Vulnerabilites related to Schneider Electric - PFXST6000, PFXSTM6000, PFXSP5000, PFXGP4100 series with Pro-face BLUE runtime
cve-2024-11999
Vulnerability from cvelistv5
Published
2024-12-17 06:13
Modified
2024-12-17 14:40
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete
control of the device when an authenticated user installs malicious code into HMI product.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | Harmony (Formerly Magelis) HMIST6, HMISTM6, HMIG3U, HMIG3X, HMISTO7 series with EcoStruxure Operator Terminal Expert runtime |
Version: All versions |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-11999", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-12-17T14:39:39.556783Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-12-17T14:40:01.736Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Harmony (Formerly Magelis) HMIST6, HMISTM6, HMIG3U, HMIG3X, HMISTO7 series with EcoStruxure Operator Terminal Expert runtime", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unaffected", "product": "PFXST6000, PFXSTM6000, PFXSP5000, PFXGP4100 series with Pro-face BLUE runtime", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete\ncontrol of the device when an authenticated user installs malicious code into HMI product.\n\n\u003cbr\u003e" } ], "value": "CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete\ncontrol of the device when an authenticated user installs malicious code into HMI product." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1104", "description": "CWE-1104 Use of Unmaintained Third-Party Components", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-17T06:13:00.636Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-345-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-345-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2024-11999", "datePublished": "2024-12-17T06:13:00.636Z", "dateReserved": "2024-11-29T15:40:40.185Z", "dateUpdated": "2024-12-17T14:40:01.736Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }