A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | Modicon M340 CPU (part numbers BMXP34*) |
Version: All < V3.30 |
||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.574Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-221-04-Modicon_Controllers_Ethernet_Modules_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2021-22786", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:54:57.011597Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:06:44.280Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Modicon M340 CPU (part numbers BMXP34*)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V3.30", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V3.20", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "product": "Modicon MC80 (BMKC80)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.6", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Modicon Momentum CPU (171CBU*)", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Legacy Modicon Quantum", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] } ], "datePublic": "2022-08-09T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200 Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-01T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-221-04-Modicon_Controllers_Ethernet_Modules_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22786", "datePublished": "2023-02-01T00:00:00.000Z", "dateReserved": "2021-01-06T00:00:00.000Z", "dateUpdated": "2025-02-05T20:06:44.280Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }