Vulnerabilites related to Dell - Dell SmartFabric OS10
cve-2023-28078
Vulnerability from cvelistv5
Published
2024-02-15 12:35
Modified
2024-08-15 17:59
Severity ?
EPSS score ?
Summary
Dell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Dell SmartFabric OS10 |
Version: 10.5.5.0 Version: 10.5.5.3 Version: 10.5.5.1 (MX) Version: 10.5.5.2 (MX) Version: 10.5.4.x Version: 10.5.4.6 (MX) Version: 10.5.3.x Version: 10.5.2.x |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:30:24.003Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "smartfabric_os10", "vendor": "dell", "versions": [ { "status": "affected", "version": "10.5.5.0" }, { "status": "affected", "version": "10.5.5.3" }, { "status": "affected", "version": "10.5.5.1\\(mx\\)" }, { "status": "affected", "version": "10.5.5.2\\(mx\\)" }, { "lessThan": "10.5.5.0", "status": "affected", "version": "10.5.2.0", "versionType": "custom" }, { "status": "affected", "version": "10.5.4.6\\(mx\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-28078", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-02-15T19:48:03.918241Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-15T17:59:34.409Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Dell SmartFabric OS10", "vendor": "Dell", "versions": [ { "status": "affected", "version": "10.5.5.0" }, { "status": "affected", "version": "10.5.5.3" }, { "status": "affected", "version": "10.5.5.1 (MX)" }, { "status": "affected", "version": "10.5.5.2 (MX)" }, { "status": "affected", "version": "10.5.4.x" }, { "status": "affected", "version": "10.5.4.6 (MX)" }, { "status": "affected", "version": "10.5.3.x" }, { "status": "affected", "version": "10.5.2.x" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Rafael Schaefer, ERNW Enno Rey Netzwerke GmbH" } ], "datePublic": "2023-08-08T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity.\u003c/span\u003e\n\n" } ], "value": "\nDell OS10 Networking Switches running 10.5.2.x and above contain a vulnerability with zeroMQ when VLT is configured. A remote unauthenticated attacker could potentially exploit this vulnerability leading to information disclosure and a possible Denial of Service when a huge number of requests are sent to the switch. This is a high severity vulnerability as it allows an attacker to view sensitive data. Dell recommends customers to upgrade at the earliest opportunity.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-923", "description": "CWE-923: Improper Restriction of Communication Channel to Intended Endpoints", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-15T12:35:00.259Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2023-28078", "datePublished": "2024-02-15T12:35:00.259Z", "dateReserved": "2023-03-10T05:10:02.997Z", "dateUpdated": "2024-08-15T17:59:34.409Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-32462
Vulnerability from cvelistv5
Published
2024-02-15 12:42
Modified
2024-08-02 15:18
Severity ?
EPSS score ?
Summary
Dell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Dell SmartFabric OS10 |
Version: 10.5.5.0 Version: 10.5.5.3 Version: 10.5.5.1 (MX) Version: 10.5.5.2 (MX) Version: 10.5.4.x Version: 10.5.4.6 (MX) Version: 10.5.3.x Version: 10.5.2.x |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-32462", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-02-15T16:56:58.249857Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:26:28.817Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T15:18:37.390Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Dell SmartFabric OS10", "vendor": "Dell", "versions": [ { "status": "affected", "version": "10.5.5.0" }, { "status": "affected", "version": "10.5.5.3" }, { "status": "affected", "version": "10.5.5.1 (MX)" }, { "status": "affected", "version": "10.5.5.2 (MX)" }, { "status": "affected", "version": "10.5.4.x" }, { "status": "affected", "version": "10.5.4.6 (MX)" }, { "status": "affected", "version": "10.5.3.x" }, { "status": "affected", "version": "10.5.2.x" } ] } ], "datePublic": "2023-08-08T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity.\u003c/span\u003e\n\n" } ], "value": "\nDell OS10 Networking Switches running 10.5.2.x and above contain an OS command injection vulnerability when using remote user authentication. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands and possible system takeover. This is a critical vulnerability as it allows an attacker to cause severe damage. Dell recommends customers to upgrade at the earliest opportunity.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-15T12:42:26.610Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000216584/dsa-2023-124-security-update-for-dell-smartfabric-os10-multiple-vulnerabilities" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2023-32462", "datePublished": "2024-02-15T12:42:26.610Z", "dateReserved": "2023-05-09T06:05:24.994Z", "dateUpdated": "2024-08-02T15:18:37.390Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }