Vulnerabilites related to Pepper+Fuchs - Comtrol IO-Link Master
cve-2020-12513
Vulnerability from cvelistv5
Published
2021-01-22 19:01
Modified
2024-09-16 17:13
Severity ?
EPSS score ?
Summary
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated blind OS Command Injection.
References
▼ | URL | Tags |
---|---|---|
https://cert.vde.com/en-us/advisories/vde-2020-038 | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Pepper+Fuchs | Comtrol IO-Link Master |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:56:52.092Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Comtrol IO-Link Master", "vendor": "Pepper+Fuchs", "versions": [ { "lessThanOrEqual": "1.5.48", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "T.Weber (SEC Consult Vulnerability Lab) reported this vulnerability. Coordinated by CERT@VDE." } ], "datePublic": "2021-01-04T00:00:00", "descriptions": [ { "lang": "en", "value": "Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated blind OS Command Injection." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-01-22T19:01:56", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ], "solutions": [ { "lang": "en", "value": "In order to prevent the exploitation of the reported vulnerabilities, we recommend that the\naffected units be updated with the following three firmware packages:\n\nU-Boot bootloader version 1.36 or newer\nSystem image version 1.52 or newer\nApplication base version 1.6.11 or newer" } ], "source": { "advisory": "VDE-2020-038", "defect": [ "VDE-2020-038" ], "discovery": "EXTERNAL" }, "title": "Pepper+Fuchs Comtrol IO-Link Master OS Command Injection", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2021-01-04T11:00:00.000Z", "ID": "CVE-2020-12513", "STATE": "PUBLIC", "TITLE": "Pepper+Fuchs Comtrol IO-Link Master OS Command Injection" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Comtrol IO-Link Master", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "1.5.48" } ] } } ] }, "vendor_name": "Pepper+Fuchs" } ] } }, "credit": [ { "lang": "eng", "value": "T.Weber (SEC Consult Vulnerability Lab) reported this vulnerability. Coordinated by CERT@VDE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated blind OS Command Injection." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78 OS Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2020-038", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ] }, "solution": [ { "lang": "en", "value": "In order to prevent the exploitation of the reported vulnerabilities, we recommend that the\naffected units be updated with the following three firmware packages:\n\nU-Boot bootloader version 1.36 or newer\nSystem image version 1.52 or newer\nApplication base version 1.6.11 or newer" } ], "source": { "advisory": "VDE-2020-038", "defect": [ "VDE-2020-038" ], "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2020-12513", "datePublished": "2021-01-22T19:01:56.657624Z", "dateReserved": "2020-04-30T00:00:00", "dateUpdated": "2024-09-16T17:13:55.439Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-12514
Vulnerability from cvelistv5
Published
2021-01-22 19:01
Modified
2024-09-16 19:40
Severity ?
EPSS score ?
Summary
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a NULL Pointer Dereference that leads to a DoS in discoveryd
References
▼ | URL | Tags |
---|---|---|
https://cert.vde.com/en-us/advisories/vde-2020-038 | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Pepper+Fuchs | Comtrol IO-Link Master |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:56:52.085Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Comtrol IO-Link Master", "vendor": "Pepper+Fuchs", "versions": [ { "lessThanOrEqual": "1.5.48", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "T.Weber (SEC Consult Vulnerability Lab) reported this vulnerability. Coordinated by CERT@VDE." } ], "datePublic": "2021-01-04T00:00:00", "descriptions": [ { "lang": "en", "value": "Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a NULL Pointer Dereference that leads to a DoS in discoveryd" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476 NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-01-22T19:01:56", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ], "solutions": [ { "lang": "en", "value": "In order to prevent the exploitation of the reported vulnerabilities, we recommend that the\naffected units be updated with the following three firmware packages:\n\nU-Boot bootloader version 1.36 or newer\nSystem image version 1.52 or newer\nApplication base version 1.6.11 or newer" } ], "source": { "advisory": "VDE-2020-038", "defect": [ "VDE-2020-038" ], "discovery": "EXTERNAL" }, "title": "Pepper+Fuchs Comtrol IO-Link Master NULL Pointer Dereference", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2021-01-04T11:00:00.000Z", "ID": "CVE-2020-12514", "STATE": "PUBLIC", "TITLE": "Pepper+Fuchs Comtrol IO-Link Master NULL Pointer Dereference" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Comtrol IO-Link Master", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "1.5.48" } ] } } ] }, "vendor_name": "Pepper+Fuchs" } ] } }, "credit": [ { "lang": "eng", "value": "T.Weber (SEC Consult Vulnerability Lab) reported this vulnerability. Coordinated by CERT@VDE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a NULL Pointer Dereference that leads to a DoS in discoveryd" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-476 NULL Pointer Dereference" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2020-038", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ] }, "solution": [ { "lang": "en", "value": "In order to prevent the exploitation of the reported vulnerabilities, we recommend that the\naffected units be updated with the following three firmware packages:\n\nU-Boot bootloader version 1.36 or newer\nSystem image version 1.52 or newer\nApplication base version 1.6.11 or newer" } ], "source": { "advisory": "VDE-2020-038", "defect": [ "VDE-2020-038" ], "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2020-12514", "datePublished": "2021-01-22T19:01:56.769686Z", "dateReserved": "2020-04-30T00:00:00", "dateUpdated": "2024-09-16T19:40:53.649Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-12511
Vulnerability from cvelistv5
Published
2021-01-22 19:01
Modified
2024-09-17 01:12
Severity ?
EPSS score ?
Summary
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a Cross-Site Request Forgery (CSRF) in the web interface.
References
▼ | URL | Tags |
---|---|---|
https://cert.vde.com/en-us/advisories/vde-2020-038 | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Pepper+Fuchs | Comtrol IO-Link Master |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:56:52.053Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Comtrol IO-Link Master", "vendor": "Pepper+Fuchs", "versions": [ { "lessThanOrEqual": "1.5.48", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "T.Weber (SEC Consult Vulnerability Lab) reported this vulnerability. Coordinated by CERT@VDE." } ], "datePublic": "2021-01-04T00:00:00", "descriptions": [ { "lang": "en", "value": "Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a Cross-Site Request Forgery (CSRF) in the web interface." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-352", "description": "CWE-352 Cross-Site Request Forgery (CSRF)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-01-22T19:01:56", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ], "solutions": [ { "lang": "en", "value": "In order to prevent the exploitation of the reported vulnerabilities, we recommend that the\naffected units be updated with the following three firmware packages:\n\nU-Boot bootloader version 1.36 or newer\nSystem image version 1.52 or newer\nApplication base version 1.6.11 or newer" } ], "source": { "advisory": "VDE-2020-038", "defect": [ "VDE-2020-038" ], "discovery": "EXTERNAL" }, "title": "Pepper+Fuchs Comtrol IO-Link Master Cross-Site Request Forgery", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2021-01-04T11:00:00.000Z", "ID": "CVE-2020-12511", "STATE": "PUBLIC", "TITLE": "Pepper+Fuchs Comtrol IO-Link Master Cross-Site Request Forgery" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Comtrol IO-Link Master", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "1.5.48" } ] } } ] }, "vendor_name": "Pepper+Fuchs" } ] } }, "credit": [ { "lang": "eng", "value": "T.Weber (SEC Consult Vulnerability Lab) reported this vulnerability. Coordinated by CERT@VDE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a Cross-Site Request Forgery (CSRF) in the web interface." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-352 Cross-Site Request Forgery (CSRF)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2020-038", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ] }, "solution": [ { "lang": "en", "value": "In order to prevent the exploitation of the reported vulnerabilities, we recommend that the\naffected units be updated with the following three firmware packages:\n\nU-Boot bootloader version 1.36 or newer\nSystem image version 1.52 or newer\nApplication base version 1.6.11 or newer" } ], "source": { "advisory": "VDE-2020-038", "defect": [ "VDE-2020-038" ], "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2020-12511", "datePublished": "2021-01-22T19:01:56.348052Z", "dateReserved": "2020-04-30T00:00:00", "dateUpdated": "2024-09-17T01:12:08.951Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-12512
Vulnerability from cvelistv5
Published
2021-01-22 19:01
Modified
2024-09-17 00:40
Severity ?
EPSS score ?
Summary
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated reflected POST Cross-Site Scripting
References
▼ | URL | Tags |
---|---|---|
https://cert.vde.com/en-us/advisories/vde-2020-038 | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Pepper+Fuchs | Comtrol IO-Link Master |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:56:52.092Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Comtrol IO-Link Master", "vendor": "Pepper+Fuchs", "versions": [ { "lessThanOrEqual": "1.5.48", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "T.Weber (SEC Consult Vulnerability Lab) reported this vulnerability. Coordinated by CERT@VDE." } ], "datePublic": "2021-01-04T00:00:00", "descriptions": [ { "lang": "en", "value": "Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated reflected POST Cross-Site Scripting" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Cross-site Scripting (XSS)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-01-22T19:01:56", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ], "solutions": [ { "lang": "en", "value": "In order to prevent the exploitation of the reported vulnerabilities, we recommend that the\naffected units be updated with the following three firmware packages:\n\nU-Boot bootloader version 1.36 or newer\nSystem image version 1.52 or newer\nApplication base version 1.6.11 or newer" } ], "source": { "advisory": "VDE-2020-038", "defect": [ "VDE-2020-038" ], "discovery": "EXTERNAL" }, "title": "Pepper+Fuchs Comtrol IO-Link Master Cross-Site Scripting", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "AKA": "", "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2021-01-04T11:00:00.000Z", "ID": "CVE-2020-12512", "STATE": "PUBLIC", "TITLE": "Pepper+Fuchs Comtrol IO-Link Master Cross-Site Scripting" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Comtrol IO-Link Master", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c=", "version_name": "", "version_value": "1.5.48" } ] } } ] }, "vendor_name": "Pepper+Fuchs" } ] } }, "configuration": [], "credit": [ { "lang": "eng", "value": "T.Weber (SEC Consult Vulnerability Lab) reported this vulnerability. Coordinated by CERT@VDE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated reflected POST Cross-Site Scripting" } ] }, "exploit": [], "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79 Cross-site Scripting (XSS)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2020-038", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2020-038" } ] }, "solution": [ { "lang": "en", "value": "In order to prevent the exploitation of the reported vulnerabilities, we recommend that the\naffected units be updated with the following three firmware packages:\n\nU-Boot bootloader version 1.36 or newer\nSystem image version 1.52 or newer\nApplication base version 1.6.11 or newer" } ], "source": { "advisory": "VDE-2020-038", "defect": [ "VDE-2020-038" ], "discovery": "EXTERNAL" }, "work_around": [] } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2020-12512", "datePublished": "2021-01-22T19:01:56.557719Z", "dateReserved": "2020-04-30T00:00:00", "dateUpdated": "2024-09-17T00:40:47.141Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }