Common Weakness Enumeration

CWE-130

Allowed

Improper Handling of Length Parameter Inconsistency

Abstraction: Base · Status: Incomplete

The product parses a formatted message or structure, but it does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data.

174 vulnerabilities reference this CWE, most recent first.

GHSA-29PR-6732-FX67

Vulnerability from github – Published: 2022-05-24 17:42 – Updated: 2025-06-13 00:33
VLAI
Details

Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool all versions, CW Configurator all versions, Data Transfer all versions, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GT SoftGOT1000 Version3 all versions, GT SoftGOT2000 Version1 all versions, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer all versions, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer all versions, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works all versions, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator all versions, MH11 SettingTool Version2 all versions, MI Configurator all versions, MT Works2 all versions, MX Component all versions, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer all versions, RT ToolBox2 all versions, RT ToolBox3 all versions, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector all versions) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2021-20588"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-119",
      "CWE-130",
      "CWE-755"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2021-02-19T20:15:00Z",
    "severity": "CRITICAL"
  },
  "details": "Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool all versions, CW Configurator all versions, Data Transfer all versions, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GT SoftGOT1000 Version3 all versions, GT SoftGOT2000 Version1 all versions, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer all versions, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer all versions, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works all versions, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator all versions, MH11 SettingTool Version2 all versions, MI Configurator all versions, MT Works2 all versions, MX Component all versions, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer all versions, RT ToolBox2 all versions, RT ToolBox3 all versions, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector all versions) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.",
  "id": "GHSA-29pr-6732-fx67",
  "modified": "2025-06-13T00:33:17Z",
  "published": "2022-05-24T17:42:41Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-20588"
    },
    {
      "type": "WEB",
      "url": "https://jvn.jp/vu/JVNVU92330101"
    },
    {
      "type": "WEB",
      "url": "https://jvn.jp/vu/JVNVU92330101/index.html"
    },
    {
      "type": "WEB",
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02"
    },
    {
      "type": "WEB",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02"
    },
    {
      "type": "WEB",
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf"
    },
    {
      "type": "WEB",
      "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2020-021_en.pdf"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-2F7G-H3X9-626R

Vulnerability from github – Published: 2022-10-14 19:00 – Updated: 2025-05-14 21:31
VLAI
Details

The communication framework module has a vulnerability of not truncating data properly.Successful exploitation of this vulnerability may affect data confidentiality.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2022-41586"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-130"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2022-10-14T16:15:00Z",
    "severity": "HIGH"
  },
  "details": "The communication framework module has a vulnerability of not truncating data properly.Successful exploitation of this vulnerability may affect data confidentiality.",
  "id": "GHSA-2f7g-h3x9-626r",
  "modified": "2025-05-14T21:31:09Z",
  "published": "2022-10-14T19:00:39Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-41586"
    },
    {
      "type": "WEB",
      "url": "https://consumer.huawei.com/en/support/bulletin/2022/10"
    },
    {
      "type": "WEB",
      "url": "https://device.harmonyos.com/en/docs/security/update/security-bulletins-phones-202210-0000001416095697"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-2MWJ-CC94-39WV

Vulnerability from github – Published: 2026-06-25 15:32 – Updated: 2026-06-25 15:32
VLAI
Details

Improper bounds validation in EmberZNet SDK versions 9.0.2 and earlier may result in crashes or dynamic memory leakage.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2026-6432"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-130"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2026-06-25T15:16:42Z",
    "severity": "MODERATE"
  },
  "details": "Improper bounds validation in EmberZNet SDK versions 9.0.2 and earlier may result in crashes or dynamic memory leakage.",
  "id": "GHSA-2mwj-cc94-39wv",
  "modified": "2026-06-25T15:32:02Z",
  "published": "2026-06-25T15:32:02Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-6432"
    },
    {
      "type": "WEB",
      "url": "https://github.com/SiliconLabsSoftware/sisdk-release"
    },
    {
      "type": "WEB",
      "url": "https://siliconlabs.lightning.force.com/sfc/servlet.shepherd/document/download/069Vm00000pYDOwIAO?operationContext=S1"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}

GHSA-3876-9WF2-9986

Vulnerability from github – Published: 2024-04-11 21:30 – Updated: 2024-04-11 21:30
VLAI
Details

Server receiving a malformed message that causes a disconnect to a hostname may causing a stack overflow resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2023-5393"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-130"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-04-11T20:15:10Z",
    "severity": "HIGH"
  },
  "details": "Server receiving a malformed message that causes a disconnect to a hostname may causing a stack overflow resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. \n\n",
  "id": "GHSA-3876-9wf2-9986",
  "modified": "2024-04-11T21:30:50Z",
  "published": "2024-04-11T21:30:50Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-5393"
    },
    {
      "type": "WEB",
      "url": "https://process.honeywell.com"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-3GQG-23CF-WQ46

Vulnerability from github – Published: 2024-04-09 18:30 – Updated: 2024-04-09 18:30
VLAI
Details

Windows Hyper-V Denial of Service Vulnerability

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2024-29064"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-130"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-04-09T17:16:00Z",
    "severity": "MODERATE"
  },
  "details": "Windows Hyper-V Denial of Service Vulnerability",
  "id": "GHSA-3gqg-23cf-wq46",
  "modified": "2024-04-09T18:30:28Z",
  "published": "2024-04-09T18:30:28Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-29064"
    },
    {
      "type": "WEB",
      "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-29064"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-3Q77-54X6-434X

Vulnerability from github – Published: 2024-07-09 18:30 – Updated: 2024-07-09 18:30
VLAI
Details

Secure Boot Security Feature Bypass Vulnerability

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2024-37988"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-130"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-07-09T17:15:26Z",
    "severity": "HIGH"
  },
  "details": "Secure Boot Security Feature Bypass Vulnerability",
  "id": "GHSA-3q77-54x6-434x",
  "modified": "2024-07-09T18:30:51Z",
  "published": "2024-07-09T18:30:51Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-37988"
    },
    {
      "type": "WEB",
      "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-37988"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-3XM3-79JV-66P7

Vulnerability from github – Published: 2022-05-06 00:00 – Updated: 2022-05-14 00:03
VLAI
Details

OCI OpenDDS versions prior to 3.18.1 do not handle a length parameter consistent with the actual length of the associated data, which may allow an attacker to remotely execute arbitrary code.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2021-38445"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-130"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2022-05-05T17:15:00Z",
    "severity": "CRITICAL"
  },
  "details": "OCI OpenDDS versions prior to 3.18.1 do not handle a length parameter consistent with the actual length of the associated data, which may allow an attacker to remotely execute arbitrary code.",
  "id": "GHSA-3xm3-79jv-66p7",
  "modified": "2022-05-14T00:03:33Z",
  "published": "2022-05-06T00:00:44Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-38445"
    },
    {
      "type": "WEB",
      "url": "https://opendds.org"
    },
    {
      "type": "WEB",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-315-02"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-45PX-VP4X-QWF2

Vulnerability from github – Published: 2026-03-10 18:31 – Updated: 2026-03-10 18:31
VLAI
Details

A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). The SICAM SIAPP SDK server component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2026-25572"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-130"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2026-03-10T18:18:37Z",
    "severity": "MODERATE"
  },
  "details": "A vulnerability has been identified in SICAM SIAPP SDK (All versions \u003c V2.1.7). The SICAM SIAPP SDK server component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service.",
  "id": "GHSA-45px-vp4x-qwf2",
  "modified": "2026-03-10T18:31:21Z",
  "published": "2026-03-10T18:31:21Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-25572"
    },
    {
      "type": "WEB",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-903736.html"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
      "type": "CVSS_V3"
    },
    {
      "score": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}

GHSA-4742-MR57-2R9J

Vulnerability from github – Published: 2025-12-19 12:31 – Updated: 2025-12-30 00:32
VLAI
Details

Mismatched length fields in Zlib compressed protocol headers may allow a read of uninitialized heap memory by an unauthenticated client. This issue affects all MongoDB Server v7.0 prior to 7.0.28 versions, MongoDB Server v8.0 versions prior to 8.0.17, MongoDB Server v8.2 versions prior to 8.2.3, MongoDB Server v6.0 versions prior to 6.0.27, MongoDB Server v5.0 versions prior to 5.0.32, MongoDB Server v4.4 versions prior to 4.4.30, MongoDB Server v4.2 versions greater than or equal to 4.2.0, MongoDB Server v4.0 versions greater than or equal to 4.0.0, and MongoDB Server v3.6 versions greater than or equal to 3.6.0.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2025-14847"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-130"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2025-12-19T11:15:49Z",
    "severity": "HIGH"
  },
  "details": "Mismatched length fields in Zlib compressed protocol headers may allow a read of uninitialized heap memory by an unauthenticated client. This issue affects all MongoDB Server v7.0 prior to 7.0.28 versions, MongoDB Server v8.0 versions prior to 8.0.17, MongoDB Server v8.2 versions prior to 8.2.3, MongoDB Server v6.0 versions prior to 6.0.27, MongoDB Server v5.0 versions prior to 5.0.32, MongoDB Server v4.4 versions prior to 4.4.30, MongoDB Server v4.2 versions greater than or equal to 4.2.0, MongoDB Server v4.0 versions greater than or equal to 4.0.0, and MongoDB Server v3.6 versions greater than or equal to 3.6.0.",
  "id": "GHSA-4742-mr57-2r9j",
  "modified": "2025-12-30T00:32:58Z",
  "published": "2025-12-19T12:31:24Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-14847"
    },
    {
      "type": "WEB",
      "url": "https://jira.mongodb.org/browse/SERVER-115508"
    },
    {
      "type": "WEB",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-14847"
    },
    {
      "type": "WEB",
      "url": "http://www.openwall.com/lists/oss-security/2025/12/29/21"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
      "type": "CVSS_V3"
    },
    {
      "score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}

GHSA-4FHF-8PH3-PP6C

Vulnerability from github – Published: 2022-09-28 00:00 – Updated: 2025-11-04 21:30
VLAI
Details

Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length and Ethernet to Wifi frame conversion (and optionally VLAN0 headers).

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2021-27862"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-130",
      "CWE-290"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2022-09-27T19:15:00Z",
    "severity": "MODERATE"
  },
  "details": "Layer 2 network filtering capabilities such as IPv6 RA guard can be bypassed using LLC/SNAP headers with invalid length and Ethernet to Wifi frame conversion (and optionally VLAN0 headers).",
  "id": "GHSA-4fhf-8ph3-pp6c",
  "modified": "2025-11-04T21:30:27Z",
  "published": "2022-09-28T00:00:18Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-27862"
    },
    {
      "type": "WEB",
      "url": "https://blog.champtar.fr/VLAN0_LLC_SNAP"
    },
    {
      "type": "WEB",
      "url": "https://datatracker.ietf.org/doc/draft-ietf-v6ops-ra-guard/08"
    },
    {
      "type": "WEB",
      "url": "https://kb.cert.org/vuls/id/855201"
    },
    {
      "type": "WEB",
      "url": "https://standards.ieee.org/ieee/802.2/1048"
    },
    {
      "type": "WEB",
      "url": "https://www.kb.cert.org/vuls/id/855201"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
      "type": "CVSS_V3"
    }
  ]
}

Mitigation
Implementation

When processing structured incoming data containing a size field followed by raw data, ensure that you identify and resolve any inconsistencies between the size field and the actual size of the data.

Mitigation
Implementation

Do not let the user control the size of the buffer.

Mitigation
Implementation

Validate that the length of the user-supplied data is consistent with the buffer size.

CAPEC-47: Buffer Overflow via Parameter Expansion

In this attack, the target software is given input that the adversary knows will be modified and expanded in size during processing. This attack relies on the target software failing to anticipate that the expanded data may exceed some internal limit, thereby creating a buffer overflow.