CWE-337
AllowedPredictable Seed in Pseudo-Random Number Generator (PRNG)
Abstraction: Variant · Status: Draft
A Pseudo-Random Number Generator (PRNG) is initialized from a predictable seed, such as the process ID or system time.
25 vulnerabilities reference this CWE, most recent first.
CVE-2022-40267 (GCVE-0-2022-40267)
Vulnerability from cvelistv5 – Published: 2023-01-20 07:52 – Updated: 2024-08-03 12:14- CWE-337 - Predictable Seed in Pseudo-Random Number Generator (PRNG)
| Vendor | Product | Version | |
|---|---|---|---|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-32MT/ES |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-64MT/ES |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Seres FX5U-80MT/ES |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-32MR/ES |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-64MR/ES |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-80MR/ES |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-32MT/DS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-64MT/DS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-80MT/DS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-32MR/DS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-64MR/DS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-80MR/DS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-32MT/ESS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-64MT/ESS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-80MT/ESS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-32MT/DSS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-64MT/DSS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5U-80MT/DSS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UC-32MT/D |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UC-64MT/D |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UC-96MT/D |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UC-32MT/DSS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UC-64MT/DSS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UC-96MT/DSS |
Affected:
serial number 17X**** or later, and versions 1.280 and prior
Affected: serial number 179**** and prior, and versions 1.074 and prior |
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UC-32MT/DS-TS |
Affected:
versions 1.280 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UC-32MT/DSS-TS |
Affected:
versions 1.280 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UC-32MR/DS-TS |
Affected:
versions 1.280 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R00CPU |
Affected:
versions 33 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R01CPU |
Affected:
versions 33 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R02CPU |
Affected:
versions 33 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R04CPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R08CPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R16CPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R32CPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R120CPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R04ENCPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R08ENCPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R16ENCPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R32ENCPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-R Series R120ENCPU |
Affected:
versions 66 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-24MT/ES |
Affected:
1.042 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-40MT/ES |
Affected:
1.042 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-60MT/ES |
Affected:
1.042 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-24MR/ES |
Affected:
1.042 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-40MR/ES |
Affected:
1.042 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-60MR/ES |
Affected:
1.042 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-24MT/ESS |
Affected:
1.042 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-40MT/ESS |
Affected:
1.042 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-60MT/ESS |
Affected:
1.042 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-24MT/ES-A |
Affected:
1.043 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-40MT/ES-A |
Affected:
1.043 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-60MT/ES-A |
Affected:
1.043 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-24MR/ES-A |
Affected:
1.043 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-40MR/ES-A |
Affected:
1.043 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5UJ-60MR/ES-A |
Affected:
1.043 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-30MT/ES |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-40MT/ES |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-60MT/ES |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-80MT/ES |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-30MR/ES |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-40MR/ES |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-60MR/ES |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-80MR/ES |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-30MT/ESS |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-40MT/ESS |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-60MT/ESS |
Affected:
1.003 and prior
|
|
| Mitsubishi Electric Corporation | MELSEC iQ-F Series FX5S-80MT/ESS |
Affected:
1.003 and prior
|
|
| mitsubishielectric | fx5u-80mt\/ess_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5u-80mt\/ess_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5u-32mt\/dss_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5u-32mt\/dss_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5u-64mt\/dss_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5u-64mt\/dss_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5u-80mt\/dss_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5u-80mt\/dss_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uc-32mt\/d_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/d_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uc-64mt\/d_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uc-64mt\/d_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uc-96mt\/d_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uc-96mt\/d_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uc-32mt\/dss_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/dss_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uc-64mt\/dss_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uc-64mt\/dss_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uc-96mt\/dss_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uc-96mt\/dss_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uc-32mt\/ds-ts_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/ds-ts_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uc-32mt\/dss-ts_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uc-32mt\/dss-ts_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uc-32mr\/ds-ts_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uc-32mr\/ds-ts_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r00cpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r00cpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r01cpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r01cpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r02cpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r02cpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r04cpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r04cpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r08cpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r08cpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r16cpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r16cpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r32cpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r32cpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r120cpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r120cpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r04encpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r04encpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r08encpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r08encpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r16encpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r16encpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r32encpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r32encpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | r120encpu_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:r120encpu_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-24mt\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-24mt\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-40mt\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-40mt\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-60mt\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-60mt\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-24mr\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-24mr\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-40mr\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-40mr\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-60mr\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-60mr\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-24mt\/ess_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-24mt\/ess_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-40mt\/ess_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-40mt\/ess_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-60mt\/ess_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-60mt\/ess_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-24mt\/es-a_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-24mt\/es-a_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-40mt\/es-a_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-40mt\/es-a_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-60mt\/es-a_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-60mt\/es-a_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-24mr\/es-a_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-24mr\/es-a_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-40mr\/es-a_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-40mr\/es-a_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5uj-60mr\/es-a_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5uj-60mr\/es-a_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-30mt\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-30mt\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-40mt\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-40mt\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-60mt\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-60mt\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-80mt\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-80mt\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-30mr\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-30mr\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-40mr\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-40mr\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-60mr\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-60mr\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-80mr\/es_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-80mr\/es_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-30mt\/ess_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-30mt\/ess_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-40mt\/ess_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-40mt\/ess_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-60mt\/ess_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-60mt\/ess_firmware:-:*:*:*:*:*:*:* |
|
| mitsubishielectric | fx5s-80mt\/ess_firmware |
Affected:
0 , ≤ 1.042
(custom)
cpe:2.3:o:mitsubishielectric:fx5s-80mt\/ess_firmware:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:14:39.972Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1646"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-019_en.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU99673580/index.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-017-02"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5u-80mt\\/ess_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5u-80mt\\/ess_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5u-32mt\\/dss_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5u-32mt\\/dss_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5u-64mt\\/dss_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5u-64mt\\/dss_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5u-80mt\\/dss_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5u-80mt\\/dss_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/d_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uc-32mt\\/d_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uc-64mt\\/d_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uc-64mt\\/d_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uc-96mt\\/d_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uc-96mt\\/d_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uc-32mt\\/dss_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uc-64mt\\/dss_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uc-64mt\\/dss_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uc-96mt\\/dss_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uc-96mt\\/dss_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/ds-ts_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uc-32mt\\/ds-ts_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss-ts_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uc-32mt\\/dss-ts_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uc-32mr\\/ds-ts_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uc-32mr\\/ds-ts_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r00cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r00cpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r01cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r01cpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r02cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r02cpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r04cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r04cpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r08cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r08cpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r16cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r16cpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r32cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r32cpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r120cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r120cpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r04encpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r04encpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r08encpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r08encpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r16encpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r16encpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r32encpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r32encpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:r120encpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "r120encpu_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-24mt\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-40mt\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-60mt\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-24mr\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-24mr\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-40mr\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-40mr\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-60mr\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-60mr\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/ess_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-24mt\\/ess_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/ess_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-40mt\\/ess_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/ess_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-60mt\\/ess_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/es-a_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-24mt\\/es-a_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/es-a_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-40mt\\/es-a_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/es-a_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-60mt\\/es-a_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-24mr\\/es-a_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-24mr\\/es-a_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-40mr\\/es-a_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-40mr\\/es-a_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5uj-60mr\\/es-a_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5uj-60mr\\/es-a_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-30mt\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-30mt\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-40mt\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-40mt\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-60mt\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-60mt\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-80mt\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-80mt\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-30mr\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-30mr\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-40mr\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-40mr\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-60mr\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-60mr\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-80mr\\/es_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-80mr\\/es_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-30mt\\/ess_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-30mt\\/ess_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-40mt\\/ess_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-40mt\\/ess_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-60mt\\/ess_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-60mt\\/ess_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:mitsubishielectric:fx5s-80mt\\/ess_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fx5s-80mt\\/ess_firmware",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "1.042",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40267",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T16:29:24.302691Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T17:23:35.219Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Seres FX5U-80MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-32MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-64MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5U-80MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-64MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-96MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-64MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-96MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "serial number 17X**** or later, and versions 1.280 and prior"
},
{
"status": "affected",
"version": "serial number 179**** and prior, and versions 1.074 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MT/DS-TS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 1.280 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MT/DSS-TS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 1.280 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UC-32MR/DS-TS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 1.280 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R00CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 33 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R01CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 33 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R02CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 33 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R04CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R08CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R16CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R32CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R120CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R04ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R08ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R16ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R32ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Series R120ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 66 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.042 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.042 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.042 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.042 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.042 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.042 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.042 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.042 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.042 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.043 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.043 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.043 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-24MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.043 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-40MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.043 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5UJ-60MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.043 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-30MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-40MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-60MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-80MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-30MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-40MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-60MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-80MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-30MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-40MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-60MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series FX5S-80MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "1.003 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Predictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-xMy/z (x=24,40,60, y=T,R, z=ES,ESS) versions 1.042 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-xMy/ES-A (x=24,40,60, y=T,R) versions 1.043 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-xMy/z (x=30,40,60,80, y=T,R, z=ES,ESS) versions 1.003 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MR/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU versions 33 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU versions 66 and prior allows a remote unauthenticated attacker to access the Web server function by guessing the random numbers used for authentication from several used random numbers."
}
],
"value": "Predictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-xMy/z (x=24,40,60, y=T,R, z=ES,ESS) versions 1.042 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-xMy/ES-A (x=24,40,60, y=T,R) versions 1.043 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-xMy/z (x=30,40,60,80, y=T,R, z=ES,ESS) versions 1.003 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MR/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU versions 33 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU versions 66 and prior allows a remote unauthenticated attacker to access the Web server function by guessing the random numbers used for authentication from several used random numbers."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-337",
"description": "CWE-337 Predictable Seed in Pseudo-Random Number Generator (PRNG) ",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T03:55:27.038Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-019_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU99673580/index.html"
},
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-017-02"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authentication Bypass Vulnerability in Web Server Function on MELSEC Series",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-40267",
"datePublished": "2023-01-20T07:52:56.784Z",
"dateReserved": "2022-09-08T19:40:16.931Z",
"dateUpdated": "2024-08-03T12:14:39.972Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26852 (GCVE-0-2022-26852)
Vulnerability from cvelistv5 – Published: 2022-04-08 19:50 – Updated: 2024-09-17 01:16- CWE-337 - Predictable Seed in Pseudo-Random Number Generator (PRNG)
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00019799… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale OneFS |
Affected:
unspecified , < 8.2.x, 9.0.0.x, 9.1.0.x, 9.2.0.x , 9.2.1.x, 9.3.0.x
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:37.716Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000197991/dell-emc-powerscale-onefs-security-update-for-multiple-component-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PowerScale OneFS",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.2.x, 9.0.0.x, 9.1.0.x, 9.2.0.x , 9.2.1.x, 9.3.0.x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-04-04T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell PowerScale OneFS, versions 8.2.x-9.3.x, contain a predictable seed in pseudo-random number generator. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to an account compromise."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-337",
"description": "CWE-337: Predictable Seed in Pseudo-Random Number Generator (PRNG)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-08T19:50:32.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000197991/dell-emc-powerscale-onefs-security-update-for-multiple-component-vulnerabilities"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2022-04-04",
"ID": "CVE-2022-26852",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerScale OneFS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "8.2.x, 9.0.0.x, 9.1.0.x, 9.2.0.x , 9.2.1.x, 9.3.0.x"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell PowerScale OneFS, versions 8.2.x-9.3.x, contain a predictable seed in pseudo-random number generator. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to an account compromise."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.1,
"baseSeverity": "High",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-337: Predictable Seed in Pseudo-Random Number Generator (PRNG)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/en-us/000197991/dell-emc-powerscale-onefs-security-update-for-multiple-component-vulnerabilities",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/en-us/000197991/dell-emc-powerscale-onefs-security-update-for-multiple-component-vulnerabilities"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2022-26852",
"datePublished": "2022-04-08T19:50:32.150Z",
"dateReserved": "2022-03-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:16:28.737Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-28597 (GCVE-0-2020-28597)
Vulnerability from cvelistv5 – Published: 2021-03-03 17:47 – Updated: 2024-08-04 16:40- CWE-337 - Predictable Seed in Pseudo-Random Number Generator (PRNG)
| URL | Tags |
|---|---|
| https://talosintelligence.com/vulnerability_repor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:40:59.576Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1221"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Epignosis",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Epignosis eFront LMS 5.2.17, Epignosis eFront LMS 5.2.21"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A predictable seed vulnerability exists in the password reset functionality of Epignosis EfrontPro 5.2.21. By predicting the seed it is possible to generate the correct password reset 1-time token. An attacker can visit the password reset supplying the password reset token to reset the password of an account of their choice."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-337",
"description": "CWE-337: Predictable Seed in Pseudo-Random Number Generator (PRNG)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-03T17:47:57.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1221"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2020-28597",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Epignosis",
"version": {
"version_data": [
{
"version_value": "Epignosis eFront LMS 5.2.17, Epignosis eFront LMS 5.2.21"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A predictable seed vulnerability exists in the password reset functionality of Epignosis EfrontPro 5.2.21. By predicting the seed it is possible to generate the correct password reset 1-time token. An attacker can visit the password reset supplying the password reset token to reset the password of an account of their choice."
}
]
},
"impact": {
"cvss": {
"baseScore": 9.8,
"baseSeverity": "Critical",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-337: Predictable Seed in Pseudo-Random Number Generator (PRNG)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1221",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1221"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2020-28597",
"datePublished": "2021-03-03T17:47:57.000Z",
"dateReserved": "2020-11-13T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:40:59.576Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-15006 (GCVE-0-2016-15006)
Vulnerability from cvelistv5 – Published: 2023-01-02 07:59 – Updated: 2024-08-06 03:47- CWE-337 - Predictable Seed in Pseudo-Random Number Generator (PRNG)
| URL | Tags |
|---|---|
| https://vuldb.com/?id.217181 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.217181 | signaturepermissions-required |
| https://github.com/pfmonville/enigmaX/commit/922b… | patch |
| https://github.com/pfmonville/enigmaX/releases/tag/2.3 | patch |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T03:47:34.787Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.217181"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.217181"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/pfmonville/enigmaX/commit/922bf90ca14a681629ba0b807a997a81d70225b5"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/pfmonville/enigmaX/releases/tag/2.3"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"modules": [
"Scrambling Table Handler"
],
"product": "enigmaX",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "2.0"
},
{
"status": "affected",
"version": "2.1"
},
{
"status": "affected",
"version": "2.2"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "tool",
"value": "VulDB GitHub Commit Analyzer"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as problematic, has been found in enigmaX up to 2.2. This issue affects the function getSeed of the file main.c of the component Scrambling Table Handler. The manipulation leads to predictable seed in pseudo-random number generator (prng). The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. Upgrading to version 2.3 is able to address this issue. The identifier of the patch is 922bf90ca14a681629ba0b807a997a81d70225b5. It is recommended to upgrade the affected component. The identifier VDB-217181 was assigned to this vulnerability."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in enigmaX bis 2.2 entdeckt. Sie wurde als problematisch eingestuft. Es geht hierbei um die Funktion getSeed der Datei main.c der Komponente Scrambling Table Handler. Durch Manipulieren mit unbekannten Daten kann eine predictable seed in pseudo-random number generator (prng)-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Die Komplexit\u00e4t eines Angriffs ist eher hoch. Die Ausnutzbarkeit gilt als schwierig. Ein Aktualisieren auf die Version 2.3 vermag dieses Problem zu l\u00f6sen. Der Patch wird als 922bf90ca14a681629ba0b807a997a81d70225b5 bezeichnet. Als bestm\u00f6gliche Massnahme wird das Einspielen eines Upgrades empfohlen."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 2.6,
"vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-337",
"description": "CWE-337 Predictable Seed in Pseudo-Random Number Generator (PRNG)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-20T09:50:09.346Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.217181"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.217181"
},
{
"tags": [
"patch"
],
"url": "https://github.com/pfmonville/enigmaX/commit/922bf90ca14a681629ba0b807a997a81d70225b5"
},
{
"tags": [
"patch"
],
"url": "https://github.com/pfmonville/enigmaX/releases/tag/2.3"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-01-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-01-02T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-01-02T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-01-26T21:05:30.000Z",
"value": "VulDB entry last update"
}
],
"title": "enigmaX Scrambling Table main.c getSeed prng seed"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2016-15006",
"datePublished": "2023-01-02T07:59:38.347Z",
"dateReserved": "2023-01-02T07:58:00.845Z",
"dateUpdated": "2024-08-06T03:47:34.787Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
GHSA-7XQ7-5JPJ-42X6
Vulnerability from github – Published: 2023-01-02 09:31 – Updated: 2023-01-09 18:30A vulnerability, which was classified as problematic, has been found in enigmaX up to 2.2. This issue affects the function getSeed of the file main.c of the component Scrambling Table Handler. The manipulation leads to predictable seed in pseudo-random number generator (prng). The attack may be initiated remotely. Upgrading to version 2.3 is able to address this issue. The name of the patch is 922bf90ca14a681629ba0b807a997a81d70225b5. It is recommended to upgrade the affected component. The identifier VDB-217181 was assigned to this vulnerability.
{
"affected": [],
"aliases": [
"CVE-2016-15006"
],
"database_specific": {
"cwe_ids": [
"CWE-337"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-01-02T08:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability, which was classified as problematic, has been found in enigmaX up to 2.2. This issue affects the function getSeed of the file main.c of the component Scrambling Table Handler. The manipulation leads to predictable seed in pseudo-random number generator (prng). The attack may be initiated remotely. Upgrading to version 2.3 is able to address this issue. The name of the patch is 922bf90ca14a681629ba0b807a997a81d70225b5. It is recommended to upgrade the affected component. The identifier VDB-217181 was assigned to this vulnerability.",
"id": "GHSA-7xq7-5jpj-42x6",
"modified": "2023-01-09T18:30:18Z",
"published": "2023-01-02T09:31:58Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2016-15006"
},
{
"type": "WEB",
"url": "https://github.com/pfmonville/enigmaX/commit/922bf90ca14a681629ba0b807a997a81d70225b5"
},
{
"type": "WEB",
"url": "https://github.com/pfmonville/enigmaX/releases/tag/2.3"
},
{
"type": "WEB",
"url": "https://vuldb.com/?ctiid.217181"
},
{
"type": "WEB",
"url": "https://vuldb.com/?id.217181"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"type": "CVSS_V3"
}
]
}
GHSA-9VV4-3CF7-MQQR
Vulnerability from github – Published: 2023-01-20 09:30 – Updated: 2023-01-30 21:30Predictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X* or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 179 and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 17X or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 179* and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MR/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU all versions, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU all versions allows a remote unauthenticated attacker to access the Web server function by guessing the random numbers used for authentication from several used random numbers.
{
"affected": [],
"aliases": [
"CVE-2022-40267"
],
"database_specific": {
"cwe_ids": [
"CWE-335",
"CWE-337"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-01-20T08:15:00Z",
"severity": "CRITICAL"
},
"details": "Predictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MR/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU all versions, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU all versions allows a remote unauthenticated attacker to access the Web server function by guessing the random numbers used for authentication from several used random numbers.",
"id": "GHSA-9vv4-3cf7-mqqr",
"modified": "2023-01-30T21:30:44Z",
"published": "2023-01-20T09:30:29Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-40267"
},
{
"type": "WEB",
"url": "https://jvn.jp/vu/JVNVU99673580/index.html"
},
{
"type": "WEB",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-017-02"
},
{
"type": "WEB",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-019_en.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"type": "CVSS_V3"
}
]
}
GHSA-GJPW-WR3X-Q236
Vulnerability from github – Published: 2025-08-06 21:31 – Updated: 2025-08-06 21:31Tigo Energy's CCA device is vulnerable to insecure session ID generation in their remote API. The session IDs are generated using a predictable method based on the current timestamp, allowing attackers to recreate valid session IDs. When combined with the ability to circumvent session ID requirements for certain commands, this enables unauthorized access to sensitive device functions on connected solar optimization systems.
{
"affected": [],
"aliases": [
"CVE-2025-7770"
],
"database_specific": {
"cwe_ids": [
"CWE-337"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-08-06T21:15:32Z",
"severity": "HIGH"
},
"details": "Tigo Energy\u0027s CCA device is vulnerable to insecure session ID generation in their remote API. The session IDs are generated using a predictable method based on the current timestamp, allowing attackers to recreate valid session IDs. When combined with the ability to circumvent session ID requirements for certain commands, this enables unauthorized access to sensitive device functions on connected solar optimization systems.",
"id": "GHSA-gjpw-wr3x-q236",
"modified": "2025-08-06T21:31:40Z",
"published": "2025-08-06T21:31:40Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-7770"
},
{
"type": "WEB",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-217-02"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
GHSA-GQ5Q-45HH-68CR
Vulnerability from github – Published: 2026-09-15 21:33 – Updated: 2026-09-15 21:33The affected products use insufficiently random values, which allows web session tokens to be predictable, bounding token entropy to the seed space.
{
"affected": [],
"aliases": [
"CVE-2026-66372"
],
"database_specific": {
"cwe_ids": [
"CWE-337"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2026-09-15T21:16:41Z",
"severity": "HIGH"
},
"details": "The affected products use insufficiently random values, which allows web session tokens to be predictable, bounding token entropy to the seed space.",
"id": "GHSA-gq5q-45hh-68cr",
"modified": "2026-09-15T21:33:03Z",
"published": "2026-09-15T21:33:03Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2026-66372"
},
{
"type": "WEB",
"url": "https://digital-watchdog.com/downloads"
},
{
"type": "WEB",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-01.json"
},
{
"type": "WEB",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-01"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"type": "CVSS_V3"
},
{
"score": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
GHSA-GR7H-XW4F-WH86
Vulnerability from github – Published: 2025-10-22 19:41 – Updated: 2025-10-24 18:27Impact
EncryptionUtilityServiceImpl initialized an AES256TextEncryptor password (serverSecretKey) using RandomStringUtils with the default java.util.Random. java.util.Random is a non‑cryptographic PRNG and can be predicted from limited state/seed information (e.g., start time window), substantially reducing the effective search space of the generated key. An attacker who can obtain ciphertexts (e.g., exported or at‑rest strings protected by this service) and approximate the PRNG seed can feasibly reconstruct the serverSecretKey and decrypt affected data.
Patches
SAK-49866 is patched in Sakai 23.5, 25.0, and trunk.
Credits
- Reported by Suraj Gangwar.
- Patched by Sam Ottenhoff (Longsight).
{
"affected": [
{
"package": {
"ecosystem": "Maven",
"name": "org.sakaiproject.kernel:sakai-kernel-impl"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"last_affected": "23.3"
}
],
"type": "ECOSYSTEM"
}
]
}
],
"aliases": [
"CVE-2025-62710"
],
"database_specific": {
"cwe_ids": [
"CWE-337"
],
"github_reviewed": true,
"github_reviewed_at": "2025-10-22T19:41:49Z",
"nvd_published_at": "2025-10-22T23:15:34Z",
"severity": "MODERATE"
},
"details": "### Impact\nEncryptionUtilityServiceImpl initialized an AES256TextEncryptor password (serverSecretKey) using RandomStringUtils with the default java.util.Random. java.util.Random is a non\u2011cryptographic PRNG and can be predicted from limited state/seed information (e.g., start time window), substantially reducing the effective search space of the generated key. An attacker who can obtain ciphertexts (e.g., exported or at\u2011rest strings protected by this service) and approximate the PRNG seed can feasibly reconstruct the serverSecretKey and decrypt affected data.\n\n### Patches\nSAK-49866 is patched in Sakai 23.5, 25.0, and trunk. \n\n### Credits\n- Reported by [Suraj Gangwar](https://www.linkedin.com/in/surajgangwar?trk=contact-info).\n- Patched by Sam Ottenhoff (Longsight).",
"id": "GHSA-gr7h-xw4f-wh86",
"modified": "2025-10-24T18:27:44Z",
"published": "2025-10-22T19:41:49Z",
"references": [
{
"type": "WEB",
"url": "https://github.com/sakaiproject/sakai/security/advisories/GHSA-gr7h-xw4f-wh86"
},
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-62710"
},
{
"type": "WEB",
"url": "https://github.com/sakaiproject/sakai/commit/bde070104b1de01f4a6458dca6d9e0880a0e3c04"
},
{
"type": "PACKAGE",
"url": "https://github.com/sakaiproject/sakai"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"type": "CVSS_V3"
}
],
"summary": "Sakai kernel-impl: predictable PRNG used to generate server\u2011side encryption key in EncryptionUtilityServiceImpl"
}
GHSA-H75P-J8XM-M278
Vulnerability from github – Published: 2026-03-06 22:08 – Updated: 2026-03-06 22:08Executive Summary
A Denial of Service vulnerability exists in CoreDNS's loop detection plugin that allows an attacker to crash the DNS server by sending specially crafted DNS queries. The vulnerability stems from the use of a predictable pseudo-random number generator (PRNG) for generating a secret query name, combined with a fatal error handler that terminates the entire process.
Technical Details
Vulnerability Description
The CoreDNS loop plugin is designed to detect forwarding loops by performing a self-test during server startup. The plugin generates a random query name (qname) using Go's math/rand package and sends an HINFO query to itself. If the server receives multiple matching queries, it assumes a forwarding loop exists and terminates.
The vulnerability arises from two design flaws:
-
Predictable PRNG Seed: The random number generator is seeded with
time.Now().UnixNano(), making the generated qname predictable if an attacker knows the approximate server start time. -
Fatal Error Handler: When the plugin detects what it believes is a loop (3+ matching HINFO queries), it calls
log.Fatalf()which invokesos.Exit(1), immediately terminating the process without cleanup or recovery.
Affected Code
File: plugin/loop/setup.go
// PRNG seeded with predictable timestamp
var r = rand.New(time.Now().UnixNano())
// Qname generation using two consecutive PRNG calls
func qname(zone string) string {
l1 := strconv.Itoa(r.Int())
l2 := strconv.Itoa(r.Int())
return dnsutil.Join(l1, l2, zone)
}
File: plugin/loop/loop.go
func (l *Loop) ServeDNS(ctx context.Context, w dns.ResponseWriter, r *dns.Msg) (int, error) {
// ... validation checks ...
if state.Name() == l.qname {
l.inc() // Increment counter
}
if l.seen() > 2 {
// FATAL: Terminates entire process
log.Fatalf("Loop (%s -> %s) detected for zone %q...", ...)
}
// ...
}
File: plugin/pkg/log/log.go
func Fatalf(format string, v ...any) {
logf(fatal, format, v...)
os.Exit(1) // Immediate process termination
}
Exploitation Window
The loop plugin remains active during the following conditions:
| Condition | Window Duration | Attack Feasibility |
|---|---|---|
| Healthy startup | 2 seconds | Requires precise timing |
| Self-test failure (upstream unreachable) | 30 seconds | HIGH - Extended window |
| Network degradation | Variable | Depends on retry behavior |
Attack Scenario
Primary Attack Vector: Network Degradation
When the upstream DNS server is unreachable (network partition, misconfiguration, outage), the loop plugin's self-test fails repeatedly. During this period:
- The loop plugin remains active for up to 30 seconds
- Each self-test attempt generates an HINFO query visible in CoreDNS logs
- An attacker with log access (shared Kubernetes cluster, centralized logging) can observe the qname
- The attacker sends 3 HINFO queries with the observed qname
- The server immediately crashes
┌──────────────────────────────────────────────────────────────────────────┐
│ ATTACK TIMELINE │
├──────────────────────────────────────────────────────────────────────────┤
│ T+0s CoreDNS starts, PRNG seeded with UnixNano() │
│ T+0.5s Self-test HINFO query sent (visible in logs) │
│ T+2s Self-test fails (upstream timeout) │
│ T+3s Retry #1 - counter resets, qname unchanged │
│ T+5s Retry #2 - attacker observes qname in logs │
│ T+5.1s ATTACKER: Send HINFO #1 → counter = 1 │
│ T+5.2s ATTACKER: Send HINFO #2 → counter = 2 │
│ T+5.3s ATTACKER: Send HINFO #3 → counter = 3 → os.Exit(1) │
│ T+5.3s SERVER CRASHES │
└──────────────────────────────────────────────────────────────────────────┘
Impact Assessment
Attack Requirements
| Requirement | Notes |
|---|---|
| Network Access | Must be able to send UDP packets to CoreDNS port |
| Log Access | Required to observe the qname (common in shared clusters) |
| Timing | Extended window during network degradation |
| Authentication | None required |
Real-World Impact
CoreDNS is the default DNS server for Kubernetes clusters. A successful attack would:
- Disruption: All DNS resolution fails within the cluster
- Cascading Failures: Services unable to discover each other
- Restart Loop: If attack persists, CoreDNS enters crash-restart cycle
- Data Plane Impact: Application-level failures across the cluster
References
- CoreDNS GitHub: https://github.com/coredns/coredns
- Loop Plugin Documentation: https://coredns.io/plugins/loop/
- Go math/rand Documentation: https://pkg.go.dev/math/rand
{
"affected": [
{
"package": {
"ecosystem": "Go",
"name": "github.com/coredns/coredns"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1.14.2"
}
],
"type": "ECOSYSTEM"
}
]
}
],
"aliases": [
"CVE-2026-26018"
],
"database_specific": {
"cwe_ids": [
"CWE-337"
],
"github_reviewed": true,
"github_reviewed_at": "2026-03-06T22:08:22Z",
"nvd_published_at": "2026-03-06T16:16:10Z",
"severity": "HIGH"
},
"details": "## Executive Summary\n\nA Denial of Service vulnerability exists in CoreDNS\u0027s loop detection plugin that allows an attacker to crash the DNS server by sending specially crafted DNS queries. The vulnerability stems from the use of a predictable pseudo-random number generator (PRNG) for generating a secret query name, combined with a fatal error handler that terminates the entire process.\n\n---\n## Technical Details\n\n### Vulnerability Description\n\nThe CoreDNS `loop` plugin is designed to detect forwarding loops by performing a self-test during server startup. The plugin generates a random query name (`qname`) using Go\u0027s `math/rand` package and sends an HINFO query to itself. If the server receives multiple matching queries, it assumes a forwarding loop exists and terminates.\n\n**The vulnerability arises from two design flaws:**\n\n1. **Predictable PRNG Seed**: The random number generator is seeded with `time.Now().UnixNano()`, making the generated qname predictable if an attacker knows the approximate server start time.\n\n2. **Fatal Error Handler**: When the plugin detects what it believes is a loop (3+ matching HINFO queries), it calls `log.Fatalf()` which invokes `os.Exit(1)`, immediately terminating the process without cleanup or recovery.\n\n### Affected Code\n\n**File: `plugin/loop/setup.go`**\n```go\n// PRNG seeded with predictable timestamp\nvar r = rand.New(time.Now().UnixNano())\n\n// Qname generation using two consecutive PRNG calls\nfunc qname(zone string) string {\n l1 := strconv.Itoa(r.Int())\n l2 := strconv.Itoa(r.Int())\n return dnsutil.Join(l1, l2, zone)\n}\n```\n\n**File: `plugin/loop/loop.go`**\n```go\nfunc (l *Loop) ServeDNS(ctx context.Context, w dns.ResponseWriter, r *dns.Msg) (int, error) {\n // ... validation checks ...\n \n if state.Name() == l.qname {\n l.inc() // Increment counter\n }\n\n if l.seen() \u003e 2 {\n // FATAL: Terminates entire process\n log.Fatalf(\"Loop (%s -\u003e %s) detected for zone %q...\", ...)\n }\n \n // ...\n}\n```\n\n**File: `plugin/pkg/log/log.go`**\n```go\nfunc Fatalf(format string, v ...any) {\n logf(fatal, format, v...)\n os.Exit(1) // Immediate process termination\n}\n```\n\n### Exploitation Window\n\nThe loop plugin remains active during the following conditions:\n\n| Condition | Window Duration | Attack Feasibility |\n|-----------|-----------------|-------------------|\n| Healthy startup | 2 seconds | Requires precise timing |\n| Self-test failure (upstream unreachable) | 30 seconds | **HIGH** - Extended window |\n| Network degradation | Variable | Depends on retry behavior |\n\n### Attack Scenario\n\n**Primary Attack Vector: Network Degradation**\n\nWhen the upstream DNS server is unreachable (network partition, misconfiguration, outage), the loop plugin\u0027s self-test fails repeatedly. During this period:\n\n1. The loop plugin remains active for up to 30 seconds\n2. Each self-test attempt generates an HINFO query visible in CoreDNS logs\n3. An attacker with log access (shared Kubernetes cluster, centralized logging) can observe the qname\n4. The attacker sends 3 HINFO queries with the observed qname\n5. The server immediately crashes\n\n```\n\u250c\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2510\n\u2502 ATTACK TIMELINE \u2502\n\u251c\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2524\n\u2502 T+0s CoreDNS starts, PRNG seeded with UnixNano() \u2502\n\u2502 T+0.5s Self-test HINFO query sent (visible in logs) \u2502\n\u2502 T+2s Self-test fails (upstream timeout) \u2502\n\u2502 T+3s Retry #1 - counter resets, qname unchanged \u2502\n\u2502 T+5s Retry #2 - attacker observes qname in logs \u2502\n\u2502 T+5.1s ATTACKER: Send HINFO #1 \u2192 counter = 1 \u2502\n\u2502 T+5.2s ATTACKER: Send HINFO #2 \u2192 counter = 2 \u2502\n\u2502 T+5.3s ATTACKER: Send HINFO #3 \u2192 counter = 3 \u2192 os.Exit(1) \u2502\n\u2502 T+5.3s SERVER CRASHES \u2502\n\u2514\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2500\u2518\n```\n\n---\n\n## Impact Assessment\n\n### Attack Requirements\n\n| Requirement | Notes |\n|-------------|-------|\n| Network Access | Must be able to send UDP packets to CoreDNS port |\n| Log Access | Required to observe the qname (common in shared clusters) |\n| Timing | Extended window during network degradation |\n| Authentication | None required |\n\n### Real-World Impact\n\nCoreDNS is the default DNS server for Kubernetes clusters. A successful attack would:\n\n1. **Disruption**: All DNS resolution fails within the cluster\n2. **Cascading Failures**: Services unable to discover each other\n3. **Restart Loop**: If attack persists, CoreDNS enters crash-restart cycle\n4. **Data Plane Impact**: Application-level failures across the cluster\n\n## References\n\n- CoreDNS GitHub: https://github.com/coredns/coredns\n- Loop Plugin Documentation: https://coredns.io/plugins/loop/\n- Go math/rand Documentation: https://pkg.go.dev/math/rand",
"id": "GHSA-h75p-j8xm-m278",
"modified": "2026-03-06T22:08:22Z",
"published": "2026-03-06T22:08:22Z",
"references": [
{
"type": "WEB",
"url": "https://github.com/coredns/coredns/security/advisories/GHSA-h75p-j8xm-m278"
},
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2026-26018"
},
{
"type": "PACKAGE",
"url": "https://github.com/coredns/coredns"
},
{
"type": "WEB",
"url": "https://github.com/coredns/coredns/releases/tag/v1.14.2"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
],
"summary": "CoreDNS Loop Detection Denial of Service Vulnerability"
}
Mitigation
Use non-predictable inputs for seed generation.
Mitigation MIT-2
Strategy: Libraries or Frameworks
Use products or modules that conform to FIPS 140-2 [REF-267] to avoid obvious entropy problems, or use the more recent FIPS 140-3 [REF-1192] if possible.
Mitigation MIT-50
Use a PRNG that periodically re-seeds itself using input from high-quality sources, such as hardware devices with high entropy. However, do not re-seed too frequently, or else the entropy source might block.
No CAPEC attack patterns related to this CWE.