Common Weakness Enumeration

CWE-121

Allowed

Stack-based Buffer Overflow

Abstraction: Variant · Status: Draft

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

5241 vulnerabilities reference this CWE, most recent first.

CVE-2017-7936 (GCVE-0-2017-7936)

Vulnerability from cvelistv5 – Published: 2017-08-07 08:00 – Updated: 2024-08-05 16:19
VLAI
Summary
A stack-based buffer overflow issue was discovered in NXP i.MX 50, i.MX 53, i.MX 6ULL, i.MX 6UltraLite, i.MX 6SoloLite, i.MX 6Solo, i.MX 6DualLite, i.MX 6SoloX, i.MX 6Dual, i.MX 6Quad, i.MX 6DualPlus, i.MX 6QuadPlus, Vybrid VF3xx, Vybrid VF5xx, and Vybrid VF6xx. When the device is configured in security enabled configuration, SDP could be used to download a small section of code to an unprotected region of memory.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a NXP i.MX Product Family Affected: NXP i.MX Product Family
Date Public
2017-08-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.271Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-152-02"
          },
          {
            "name": "99966",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99966"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NXP i.MX Product Family",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "NXP i.MX Product Family"
            }
          ]
        }
      ],
      "datePublic": "2017-08-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack-based buffer overflow issue was discovered in NXP i.MX 50, i.MX 53, i.MX 6ULL, i.MX 6UltraLite, i.MX 6SoloLite, i.MX 6Solo, i.MX 6DualLite, i.MX 6SoloX, i.MX 6Dual, i.MX 6Quad, i.MX 6DualPlus, i.MX 6QuadPlus, Vybrid VF3xx, Vybrid VF5xx, and Vybrid VF6xx. When the device is configured in security enabled configuration, SDP could be used to download a small section of code to an unprotected region of memory."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-07T09:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-152-02"
        },
        {
          "name": "99966",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99966"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7936",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NXP i.MX Product Family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "NXP i.MX Product Family"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A stack-based buffer overflow issue was discovered in NXP i.MX 50, i.MX 53, i.MX 6ULL, i.MX 6UltraLite, i.MX 6SoloLite, i.MX 6Solo, i.MX 6DualLite, i.MX 6SoloX, i.MX 6Dual, i.MX 6Quad, i.MX 6DualPlus, i.MX 6QuadPlus, Vybrid VF3xx, Vybrid VF5xx, and Vybrid VF6xx. When the device is configured in security enabled configuration, SDP could be used to download a small section of code to an unprotected region of memory."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-152-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-152-02"
            },
            {
              "name": "99966",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99966"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7936",
    "datePublished": "2017-08-07T08:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.271Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7910 (GCVE-0-2017-7910)

Vulnerability from cvelistv5 – Published: 2017-06-14 21:00 – Updated: 2024-08-05 16:19
VLAI
Summary
A Stack-Based Buffer Overflow issue was discovered in Digital Canal Structural Wind Analysis versions 9.1 and prior. An attacker may be able to run arbitrary code by remotely exploiting an executable to perform a denial-of-service attack.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Digital Canal Structural Wind Analysis Affected: Digital Canal Structural Wind Analysis
Date Public
2017-06-14 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.211Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-157-02"
          },
          {
            "name": "98976",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98976"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Digital Canal Structural Wind Analysis",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Digital Canal Structural Wind Analysis"
            }
          ]
        }
      ],
      "datePublic": "2017-06-14T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Stack-Based Buffer Overflow issue was discovered in Digital Canal Structural Wind Analysis versions 9.1 and prior. An attacker may be able to run arbitrary code by remotely exploiting an executable to perform a denial-of-service attack."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-15T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-157-02"
        },
        {
          "name": "98976",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98976"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7910",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Digital Canal Structural Wind Analysis",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Digital Canal Structural Wind Analysis"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Stack-Based Buffer Overflow issue was discovered in Digital Canal Structural Wind Analysis versions 9.1 and prior. An attacker may be able to run arbitrary code by remotely exploiting an executable to perform a denial-of-service attack."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-157-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-157-02"
            },
            {
              "name": "98976",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/98976"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7910",
    "datePublished": "2017-06-14T21:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.211Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6035 (GCVE-0-2017-6035)

Vulnerability from cvelistv5 – Published: 2017-04-27 00:00 – Updated: 2024-08-05 15:18
VLAI
Summary
A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow, which could result in denial of service when a malicious project file is run on the system.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Wecon Technologies LEVI Studio HMI Editor Affected: Wecon Technologies LEVI Studio HMI Editor
Date Public
2017-04-26 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.405Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "97639",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97639"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-103-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Wecon Technologies LEVI Studio HMI Editor",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Wecon Technologies LEVI Studio HMI Editor"
            }
          ]
        }
      ],
      "datePublic": "2017-04-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow, which could result in denial of service when a malicious project file is run on the system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-04-27T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "97639",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97639"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-103-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6035",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Wecon Technologies LEVI Studio HMI Editor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Wecon Technologies LEVI Studio HMI Editor"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow, which could result in denial of service when a malicious project file is run on the system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "97639",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97639"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-103-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-103-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6035",
    "datePublished": "2017-04-27T00:00:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:18:49.405Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6025 (GCVE-0-2017-6025)

Vulnerability from cvelistv5 – Published: 2017-05-19 02:43 – Updated: 2024-08-05 15:18
VLAI
Summary
A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a 3S-Smart Software Solutions GmbH CODESYS Web Server Affected: 3S-Smart Software Solutions GmbH CODESYS Web Server
Date Public
2017-05-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.399Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "97174",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97174"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-087-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "3S-Smart Software Solutions GmbH CODESYS Web Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "3S-Smart Software Solutions GmbH CODESYS Web Server"
            }
          ]
        }
      ],
      "datePublic": "2017-05-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-05-19T09:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "97174",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97174"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-087-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6025",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "3S-Smart Software Solutions GmbH CODESYS Web Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "3S-Smart Software Solutions GmbH CODESYS Web Server"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "97174",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97174"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-087-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-087-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6025",
    "datePublished": "2017-05-19T02:43:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:18:49.399Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6023 (GCVE-0-2017-6023)

Vulnerability from cvelistv5 – Published: 2017-03-16 03:49 – Updated: 2024-08-05 15:18
VLAI
Summary
An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Fatek Automation PLC Ethernet Module Affected: Fatek Automation PLC Ethernet Module
Date Public
2017-03-15 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.609Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "96892",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/96892"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-073-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fatek Automation PLC Ethernet Module",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Fatek Automation PLC Ethernet Module"
            }
          ]
        }
      ],
      "datePublic": "2017-03-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-03-16T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "96892",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/96892"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-073-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6023",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fatek Automation PLC Ethernet Module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Fatek Automation PLC Ethernet Module"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "96892",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/96892"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-073-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-073-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6023",
    "datePublished": "2017-03-16T03:49:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:18:49.609Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5177 (GCVE-0-2017-5177)

Vulnerability from cvelistv5 – Published: 2017-05-19 02:43 – Updated: 2024-08-05 14:55
VLAI
Summary
A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length buffer. This could allow remote code execution.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a VIPA Controls WinPLC7 Affected: VIPA Controls WinPLC7
Date Public
2017-05-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:34.856Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "42693",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/42693/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-01"
          },
          {
            "name": "96413",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/96413"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VIPA Controls WinPLC7",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "VIPA Controls WinPLC7"
            }
          ]
        }
      ],
      "datePublic": "2017-05-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length buffer. This could allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-09-15T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "42693",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/42693/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-01"
        },
        {
          "name": "96413",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/96413"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-5177",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VIPA Controls WinPLC7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "VIPA Controls WinPLC7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length buffer. This could allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "42693",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/42693/"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-01"
            },
            {
              "name": "96413",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/96413"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-5177",
    "datePublished": "2017-05-19T02:43:00.000Z",
    "dateReserved": "2017-01-03T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:55:34.856Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-3223 (GCVE-0-2017-3223)

Vulnerability from cvelistv5 – Published: 2018-07-24 15:00 – Updated: 2024-08-05 14:16
VLAI
Title
Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow
Summary
Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow. Dahua IP camera products include an application known as Sonia (/usr/bin/sonia) that provides the web interface and other services for controlling the IP camera remotely. Versions of Sonia included in firmware versions prior to DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 do not validate input data length for the 'password' field of the web interface. A remote, unauthenticated attacker may submit a crafted POST request to the IP camera's Sonia web interface that may lead to out-of-bounds memory operations and loss of availability or remote code execution. The issue was originally identified by the researcher in firmware version DH_IPC-HX1X2X-Themis_EngSpnFrn_N_V2.400.0000.30.R.20160803.
Severity
No CVSS data available.
CWE
Assigner
References
URL Tags
https://www.kb.cert.org/vuls/id/547255 third-party-advisoryx_refsource_CERT-VN
http://www.securityfocus.com/bid/99620 vdb-entryx_refsource_BID
Impacted products
Vendor Product Version
Dahua IP Camera Affected: DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 , < DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 (custom)
Create a notification for this product.
Date Public
2017-07-18 00:00
Credits
Thanks to Ilya Smith of Positive Technologies for reporting this vulnerability.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:16:28.415Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VU#547255",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "https://www.kb.cert.org/vuls/id/547255"
          },
          {
            "name": "99620",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99620"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IP Camera",
          "vendor": "Dahua",
          "versions": [
            {
              "lessThan": "DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621",
              "status": "affected",
              "version": "DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Thanks to Ilya Smith of Positive Technologies for reporting this vulnerability."
        }
      ],
      "datePublic": "2017-07-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow. Dahua IP camera products include an application known as Sonia (/usr/bin/sonia) that provides the web interface and other services for controlling the IP camera remotely. Versions of Sonia included in firmware versions prior to DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 do not validate input data length for the \u0027password\u0027 field of the web interface. A remote, unauthenticated attacker may submit a crafted POST request to the IP camera\u0027s Sonia web interface that may lead to out-of-bounds memory operations and loss of availability or remote code execution. The issue was originally identified by the researcher in firmware version DH_IPC-HX1X2X-Themis_EngSpnFrn_N_V2.400.0000.30.R.20160803."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-25T09:57:01.000Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "name": "VU#547255",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "https://www.kb.cert.org/vuls/id/547255"
        },
        {
          "name": "99620",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99620"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Dahua has released firmware version DH_IPC-ACK-Themis_Eng_P_V2.400.0000.14.R.20170713.bin to address this issue"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2017-3223",
          "STATE": "PUBLIC",
          "TITLE": "Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IP Camera",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621",
                            "version_value": "DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dahua"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Thanks to Ilya Smith of Positive Technologies for reporting this vulnerability."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow. Dahua IP camera products include an application known as Sonia (/usr/bin/sonia) that provides the web interface and other services for controlling the IP camera remotely. Versions of Sonia included in firmware versions prior to DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 do not validate input data length for the \u0027password\u0027 field of the web interface. A remote, unauthenticated attacker may submit a crafted POST request to the IP camera\u0027s Sonia web interface that may lead to out-of-bounds memory operations and loss of availability or remote code execution. The issue was originally identified by the researcher in firmware version DH_IPC-HX1X2X-Themis_EngSpnFrn_N_V2.400.0000.30.R.20160803."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "VU#547255",
              "refsource": "CERT-VN",
              "url": "https://www.kb.cert.org/vuls/id/547255"
            },
            {
              "name": "99620",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99620"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Dahua has released firmware version DH_IPC-ACK-Themis_Eng_P_V2.400.0000.14.R.20170713.bin to address this issue"
          }
        ],
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2017-3223",
    "datePublished": "2018-07-24T15:00:00.000Z",
    "dateReserved": "2016-12-05T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:16:28.415Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-3195 (GCVE-0-2017-3195)

Vulnerability from cvelistv5 – Published: 2017-12-15 14:00 – Updated: 2024-08-05 14:16
VLAI
Summary
Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges.
Severity
No CVSS data available.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
http://kb.commvault.com/article/SEC0013 x_refsource_CONFIRM
http://redr2e.com/commvault-edge-cve-2017-3195/ x_refsource_MISC
https://www.exploit-db.com/exploits/41823/ exploitx_refsource_EXPLOIT-DB
https://www.kb.cert.org/vuls/id/214283 third-party-advisoryx_refsource_CERT-VN
http://www.securityfocus.com/bid/96941 vdb-entryx_refsource_BID
Impacted products
Vendor Product Version
Commvault Service Pack 6 Affected: Version 11 prior to SP7
Affected: version 11 SP6 prior to hotfix 590
Create a notification for this product.
Date Public
2017-03-16 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:16:28.351Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://kb.commvault.com/article/SEC0013"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://redr2e.com/commvault-edge-cve-2017-3195/"
          },
          {
            "name": "41823",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/41823/"
          },
          {
            "name": "VU#214283",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "https://www.kb.cert.org/vuls/id/214283"
          },
          {
            "name": "96941",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/96941"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Service Pack 6",
          "vendor": "Commvault",
          "versions": [
            {
              "status": "affected",
              "version": "Version 11 prior to SP7"
            },
            {
              "status": "affected",
              "version": "version 11 SP6 prior to hotfix 590"
            }
          ]
        }
      ],
      "datePublic": "2017-03-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-15T13:57:01.000Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://kb.commvault.com/article/SEC0013"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://redr2e.com/commvault-edge-cve-2017-3195/"
        },
        {
          "name": "41823",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/41823/"
        },
        {
          "name": "VU#214283",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "https://www.kb.cert.org/vuls/id/214283"
        },
        {
          "name": "96941",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/96941"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2017-3195",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Service Pack 6",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version 11 prior to SP7"
                          },
                          {
                            "version_value": "version 11 SP6 prior to hotfix 590"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Commvault"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://kb.commvault.com/article/SEC0013",
              "refsource": "CONFIRM",
              "url": "http://kb.commvault.com/article/SEC0013"
            },
            {
              "name": "http://redr2e.com/commvault-edge-cve-2017-3195/",
              "refsource": "MISC",
              "url": "http://redr2e.com/commvault-edge-cve-2017-3195/"
            },
            {
              "name": "41823",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/41823/"
            },
            {
              "name": "VU#214283",
              "refsource": "CERT-VN",
              "url": "https://www.kb.cert.org/vuls/id/214283"
            },
            {
              "name": "96941",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/96941"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2017-3195",
    "datePublished": "2017-12-15T14:00:00.000Z",
    "dateReserved": "2016-12-05T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:16:28.351Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-3193 (GCVE-0-2017-3193)

Vulnerability from cvelistv5 – Published: 2017-12-15 14:00 – Updated: 2024-08-05 14:16
VLAI
Summary
Multiple D-Link devices including the DIR-850L firmware versions 1.14B07 and 2.07.B05 contain a stack-based buffer overflow vulnerability in the web administration interface HNAP service.
Severity
No CVSS data available.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
D-Link DIR-850L and potentially others Affected: 1.14B07
Affected: 2.07.B05
Create a notification for this product.
Date Public
2017-03-08 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:16:28.328Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VU#305448",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "https://www.kb.cert.org/vuls/id/305448"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://twitter.com/NCCGroupInfosec/status/845269159277723649"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.nccgroup.trust/uk/our-research/d-link-dir-850l-web-admin-interface-vulnerable-to-stack-based-buffer-overflow/?research=Technical+advisories"
          },
          {
            "name": "96747",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/96747"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/viewAlert.x?alertId=52967"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DIR-850L and potentially others",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "1.14B07"
            },
            {
              "status": "affected",
              "version": "2.07.B05"
            }
          ]
        }
      ],
      "datePublic": "2017-03-08T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple D-Link devices including the DIR-850L firmware versions 1.14B07 and 2.07.B05 contain a stack-based buffer overflow vulnerability in the web administration interface HNAP service."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-15T13:57:01.000Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "name": "VU#305448",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "https://www.kb.cert.org/vuls/id/305448"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://twitter.com/NCCGroupInfosec/status/845269159277723649"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.nccgroup.trust/uk/our-research/d-link-dir-850l-web-admin-interface-vulnerable-to-stack-based-buffer-overflow/?research=Technical+advisories"
        },
        {
          "name": "96747",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/96747"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://tools.cisco.com/security/center/viewAlert.x?alertId=52967"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2017-3193",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DIR-850L and potentially others",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.14B07"
                          },
                          {
                            "version_value": "2.07.B05"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "D-Link"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple D-Link devices including the DIR-850L firmware versions 1.14B07 and 2.07.B05 contain a stack-based buffer overflow vulnerability in the web administration interface HNAP service."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "VU#305448",
              "refsource": "CERT-VN",
              "url": "https://www.kb.cert.org/vuls/id/305448"
            },
            {
              "name": "https://twitter.com/NCCGroupInfosec/status/845269159277723649",
              "refsource": "MISC",
              "url": "https://twitter.com/NCCGroupInfosec/status/845269159277723649"
            },
            {
              "name": "https://www.nccgroup.trust/uk/our-research/d-link-dir-850l-web-admin-interface-vulnerable-to-stack-based-buffer-overflow/?research=Technical+advisories",
              "refsource": "MISC",
              "url": "https://www.nccgroup.trust/uk/our-research/d-link-dir-850l-web-admin-interface-vulnerable-to-stack-based-buffer-overflow/?research=Technical+advisories"
            },
            {
              "name": "96747",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/96747"
            },
            {
              "name": "https://tools.cisco.com/security/center/viewAlert.x?alertId=52967",
              "refsource": "MISC",
              "url": "https://tools.cisco.com/security/center/viewAlert.x?alertId=52967"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2017-3193",
    "datePublished": "2017-12-15T14:00:00.000Z",
    "dateReserved": "2016-12-05T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:16:28.328Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-2630 (GCVE-0-2017-2630)

Vulnerability from cvelistv5 – Published: 2018-07-27 18:00 – Updated: 2024-08-05 14:02
VLAI
Summary
A stack buffer overflow flaw was found in the Quick Emulator (QEMU) before 2.9 built with the Network Block Device (NBD) client support. The flaw could occur while processing server's response to a 'NBD_OPT_LIST' request. A malicious NBD server could use this issue to crash a remote NBD client resulting in DoS or potentially execute arbitrary code on client host with privileges of the QEMU process.
CWE
Assigner
Impacted products
Vendor Product Version
QEMU Qemu: Affected: 2.9
Create a notification for this product.
Date Public
2017-02-03 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.177Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "RHSA-2017:2392",
            "tags": [
              "vendor-advisory",
              "x_refsource_REDHAT",
              "x_transferred"
            ],
            "url": "https://access.redhat.com/errata/RHSA-2017:2392"
          },
          {
            "name": "96265",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/96265"
          },
          {
            "name": "GLSA-201704-01",
            "tags": [
              "vendor-advisory",
              "x_refsource_GENTOO",
              "x_transferred"
            ],
            "url": "https://security.gentoo.org/glsa/201704-01"
          },
          {
            "name": "[oss-security] 20170215 CVE-2017-2630 Qemu: nbd: oob stack write in client routine drop_sync",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2017/02/15/2"
          },
          {
            "name": "[qemu-devel] 20170206 [PATCH 05/18] nbd/client: fix drop_sync",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "https://lists.gnu.org/archive/html/qemu-devel/2017-02/msg01246.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2630"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1422415"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/qemu/qemu/commit/2563c9c6b8670400c48e562034b321a7cf3d9a85"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Qemu:",
          "vendor": "QEMU",
          "versions": [
            {
              "status": "affected",
              "version": "2.9"
            }
          ]
        }
      ],
      "datePublic": "2017-02-03T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack buffer overflow flaw was found in the Quick Emulator (QEMU) before 2.9 built with the Network Block Device (NBD) client support. The flaw could occur while processing server\u0027s response to a \u0027NBD_OPT_LIST\u0027 request. A malicious NBD server could use this issue to crash a remote NBD client resulting in DoS or potentially execute arbitrary code on client host with privileges of the QEMU process."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-08T12:55:04.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "name": "RHSA-2017:2392",
          "tags": [
            "vendor-advisory",
            "x_refsource_REDHAT"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2017:2392"
        },
        {
          "name": "96265",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/96265"
        },
        {
          "name": "GLSA-201704-01",
          "tags": [
            "vendor-advisory",
            "x_refsource_GENTOO"
          ],
          "url": "https://security.gentoo.org/glsa/201704-01"
        },
        {
          "name": "[oss-security] 20170215 CVE-2017-2630 Qemu: nbd: oob stack write in client routine drop_sync",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2017/02/15/2"
        },
        {
          "name": "[qemu-devel] 20170206 [PATCH 05/18] nbd/client: fix drop_sync",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "https://lists.gnu.org/archive/html/qemu-devel/2017-02/msg01246.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2630"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1422415"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/qemu/qemu/commit/2563c9c6b8670400c48e562034b321a7cf3d9a85"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2017-2630",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Qemu:",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2.9"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "QEMU"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A stack buffer overflow flaw was found in the Quick Emulator (QEMU) before 2.9 built with the Network Block Device (NBD) client support. The flaw could occur while processing server\u0027s response to a \u0027NBD_OPT_LIST\u0027 request. A malicious NBD server could use this issue to crash a remote NBD client resulting in DoS or potentially execute arbitrary code on client host with privileges of the QEMU process."
            }
          ]
        },
        "impact": {
          "cvss": [
            [
              {
                "vectorString": "5.5/CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:L/I:L/A:L",
                "version": "3.0"
              }
            ],
            [
              {
                "vectorString": "4.6/AV:N/AC:H/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ]
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "RHSA-2017:2392",
              "refsource": "REDHAT",
              "url": "https://access.redhat.com/errata/RHSA-2017:2392"
            },
            {
              "name": "96265",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/96265"
            },
            {
              "name": "GLSA-201704-01",
              "refsource": "GENTOO",
              "url": "https://security.gentoo.org/glsa/201704-01"
            },
            {
              "name": "[oss-security] 20170215 CVE-2017-2630 Qemu: nbd: oob stack write in client routine drop_sync",
              "refsource": "MLIST",
              "url": "http://www.openwall.com/lists/oss-security/2017/02/15/2"
            },
            {
              "name": "[qemu-devel] 20170206 [PATCH 05/18] nbd/client: fix drop_sync",
              "refsource": "MLIST",
              "url": "https://lists.gnu.org/archive/html/qemu-devel/2017-02/msg01246.html"
            },
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2630",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2630"
            },
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=1422415",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1422415"
            },
            {
              "name": "https://github.com/qemu/qemu/commit/2563c9c6b8670400c48e562034b321a7cf3d9a85",
              "refsource": "MISC",
              "url": "https://github.com/qemu/qemu/commit/2563c9c6b8670400c48e562034b321a7cf3d9a85"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2017-2630",
    "datePublished": "2018-07-27T18:00:00.000Z",
    "dateReserved": "2016-12-01T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:02:07.177Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation MIT-10
Operation Build and Compilation

Strategy: Environment Hardening

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Architecture and Design

Use an abstraction library to abstract away risky APIs. Not a complete solution.

Mitigation
Implementation

Implement and perform bounds checking on input.

Mitigation
Implementation

Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.

Mitigation MIT-11
Operation Build and Compilation

Strategy: Environment Hardening

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.