{"vulnerability": "CVE-2011-4050", "sightings": [{"uuid": "c612c8fb-5614-4aa8-9792-1b71c774d88b", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2011-4050", "type": "seen", "source": "MISP/a1e796df-2ad8-4c8d-8b69-737a004e72dd", "content": "", "creation_timestamp": "2025-02-06T03:13:40.000000Z"}, {"uuid": "7cdd6bfb-9a31-4580-9213-e9447dc78058", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2011-4050", "type": "seen", "source": "MISP/a1e796df-2ad8-4c8d-8b69-737a004e72dd", "content": "", "creation_timestamp": "2025-02-23T04:08:58.000000Z"}, {"uuid": "50358c47-8e61-47a3-8608-0c3198206ee8", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2011-4050", "type": "seen", "source": "https://github.com/rapid7/metasploit-framework/blob/master/modules/auxiliary/dos/scada/igss9_dataserver.rb", "content": "", "creation_timestamp": "2018-05-29T15:50:33.000000Z"}, {"uuid": "b6c661a2-fed5-492f-99b2-7a590c0dff29", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2011-4050", "type": "seen", "source": "https://github.com/rapid7/metasploit-framework/blob/master/modules/auxiliary/dos/scada/igss9_dataserver.rb", "content": "{\"actions\": [], \"aliases\": [], \"arch\": \"\", \"author\": [\"jfa\"], \"autofilter_ports\": [], \"autofilter_services\": [], \"check\": false, \"default_credential\": false, \"description\": \"The 7-Technologies SCADA IGSS Data Server (IGSSdataServer.exe) &lt;= 9.0.0.10306 can be\\n          brought down by sending a crafted TCP packet to port 12401.  This should also work\\n          for version &lt;= 9.0.0.1120, but that version hasn't been tested.\", \"disclosure_date\": \"2011-12-20\", \"fullname\": \"auxiliary/dos/scada/igss9_dataserver\", \"is_install_path\": true, \"mod_time\": \"2025-05-15 08:43:24 +0000\", \"name\": \"7-Technologies IGSS 9 IGSSdataServer.exe DoS\", \"needs_cleanup\": false, \"notes\": {\"Reliability\": [], \"SideEffects\": [], \"Stability\": [\"crash-service-down\"]}, \"path\": \"/modules/auxiliary/dos/scada/igss9_dataserver.rb\", \"platform\": \"\", \"post_auth\": false, \"rank\": 300, \"ref_name\": \"dos/scada/igss9_dataserver\", \"references\": [\"CVE-2011-4050\", \"OSVDB-77976\", \"URL-https://www.cisa.gov/uscert/ics/advisories/ICSA-11-335-01\"], \"rport\": 12401, \"session_types\": false, \"targets\": null, \"type\": \"auxiliary\"}", "creation_timestamp": "2026-09-08T06:47:03.553199Z"}]}