<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent sightings.</title>
    <link>https://vulnerability.circl.lu</link>
    <description>Contains only the most 10 recent sightings.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 03 Jul 2026 14:06:55 +0000</lastBuildDate>
    <item>
      <title>13496a22-7e3b-4d7c-a343-da30d5455699</title>
      <link>https://vulnerability.circl.lu/sighting/13496a22-7e3b-4d7c-a343-da30d5455699/export</link>
      <description>{"uuid": "13496a22-7e3b-4d7c-a343-da30d5455699", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-28660", "type": "seen", "source": "https://infosec.exchange/users/certvde/statuses/116838675578498232", "content": "#OT #Advisory VDE-2026-049Balluff GmbH: Multiple Vulnerabilities Affecting BNI EGW-720-007-K095 and BAV MA-NC-00025-01\nSecurity advisory for Balluff BNI EGW-720-007-K095 and BAV MA-NC-00025-01 firmware versions prior to 2.4.1. This advisory covers multiple vulnerabilities affecting software components used by the device firmware.#CVE CVE-2025-68121, CVE-2026-1229, CVE-2025-41115, CVE-2025-15467, CVE-2023-3128, CVE-2022-28660, CVE-2022-26148, CVE-2018-15727, CVE-2020-27846, CVE-2024-9264, CVE-2024-1442, CVE-2022-28391, CVE-2022-24812, CVE-2022-23498, CVE-2022-21703, CVE-2022-31097, CVE-2025-61732, CVE-2025-4674, CVE-2022-29170, CVE-2024-56406\nhttps://certvde.com/en/advisories/vde-2026-049/\n#CSAF https://balluff.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-049.json", "creation_timestamp": "2026-06-30T10:51:46.273960Z"}</description>
      <content:encoded>{"uuid": "13496a22-7e3b-4d7c-a343-da30d5455699", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-28660", "type": "seen", "source": "https://infosec.exchange/users/certvde/statuses/116838675578498232", "content": "#OT #Advisory VDE-2026-049Balluff GmbH: Multiple Vulnerabilities Affecting BNI EGW-720-007-K095 and BAV MA-NC-00025-01\nSecurity advisory for Balluff BNI EGW-720-007-K095 and BAV MA-NC-00025-01 firmware versions prior to 2.4.1. This advisory covers multiple vulnerabilities affecting software components used by the device firmware.#CVE CVE-2025-68121, CVE-2026-1229, CVE-2025-41115, CVE-2025-15467, CVE-2023-3128, CVE-2022-28660, CVE-2022-26148, CVE-2018-15727, CVE-2020-27846, CVE-2024-9264, CVE-2024-1442, CVE-2022-28391, CVE-2022-24812, CVE-2022-23498, CVE-2022-21703, CVE-2022-31097, CVE-2025-61732, CVE-2025-4674, CVE-2022-29170, CVE-2024-56406\nhttps://certvde.com/en/advisories/vde-2026-049/\n#CSAF https://balluff.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-049.json", "creation_timestamp": "2026-06-30T10:51:46.273960Z"}</content:encoded>
      <guid isPermaLink="false">https://vulnerability.circl.lu/sighting/13496a22-7e3b-4d7c-a343-da30d5455699/export</guid>
      <pubDate>Tue, 30 Jun 2026 10:51:46 +0000</pubDate>
    </item>
    <item>
      <title>c0f72b26-3533-4857-b000-b47581cf1e54</title>
      <link>https://vulnerability.circl.lu/sighting/c0f72b26-3533-4857-b000-b47581cf1e54/export</link>
      <description>{"uuid": "c0f72b26-3533-4857-b000-b47581cf1e54", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-28660", "type": "seen", "source": "https://t.me/cibsecurity/43060", "content": "\u203c CVE-2022-28660 \u203c\n\nThe querier component in Grafana Enterprise Logs 1.1.x through 1.3.x before 1.4.0 does not require authentication when X-Scope-OrgID is used. Versions 1.2.1, 1.3.1, and 1.4.0 contain the bugfix. This affects -auth.type=enterprise in microservices mode\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2022-05-20T18:31:31.000000Z"}</description>
      <content:encoded>{"uuid": "c0f72b26-3533-4857-b000-b47581cf1e54", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-28660", "type": "seen", "source": "https://t.me/cibsecurity/43060", "content": "\u203c CVE-2022-28660 \u203c\n\nThe querier component in Grafana Enterprise Logs 1.1.x through 1.3.x before 1.4.0 does not require authentication when X-Scope-OrgID is used. Versions 1.2.1, 1.3.1, and 1.4.0 contain the bugfix. This affects -auth.type=enterprise in microservices mode\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2022-05-20T18:31:31.000000Z"}</content:encoded>
      <guid isPermaLink="false">https://vulnerability.circl.lu/sighting/c0f72b26-3533-4857-b000-b47581cf1e54/export</guid>
      <pubDate>Fri, 20 May 2022 18:31:31 +0000</pubDate>
    </item>
  </channel>
</rss>
