Search

Find a vulnerability

Search criteria ⓘ Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    20 vulnerabilities found for hg9 by tenda

    CVE-2026-104610 (GCVE-0-2026-104610)

    Vulnerability from nvd – Published: 2026-10-02 12:00 – Updated: 2026-10-02 13:50
    VLAI
    Title
    Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 13:49 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/412917 vdb-entrytechnical-description
    https://vuldb.com/vuln/412917/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-104610 third-party-advisory
    https://vuldb.com/submit/962541 third-party-advisory
    https://github.com/Expl0rer-Ct/CVE/issues/1 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-104610",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T13:49:47.985467Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T13:50:12.393Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Expl0rer.Ct (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T12:00:18.544Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-412917 | Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/412917"
            },
            {
              "name": "VDB-412917 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/412917/cti"
            },
            {
              "name": "CVE-2026-104610 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-104610"
            },
            {
              "name": "Submit #962541 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/962541"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/Expl0rer-Ct/CVE/issues/1"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:54:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-104610",
        "datePublished": "2026-10-02T12:00:18.544Z",
        "dateReserved": "2026-10-02T03:49:26.992Z",
        "dateUpdated": "2026-10-02T13:50:12.393Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11553 (GCVE-0-2026-11553)

    Vulnerability from nvd – Published: 2026-06-08 17:15 – Updated: 2026-10-02 03:49
    VLAI
    Title
    Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 18:49 UTC
    CWE
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11553",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T18:49:04.954919Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T18:49:14.135Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "zhihua xie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T03:49:03.652Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369163 | Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369163"
            },
            {
              "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369163/cti"
            },
            {
              "name": "CVE-2026-11553 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11553"
            },
            {
              "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836778"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:53:43.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11553",
        "datePublished": "2026-06-08T17:15:11.855Z",
        "dateReserved": "2026-06-08T05:43:31.214Z",
        "dateUpdated": "2026-10-02T03:49:03.652Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11499 (GCVE-0-2026-11499)

    Vulnerability from nvd – Published: 2026-06-08 07:00 – Updated: 2026-10-02 03:48
    VLAI
    Title
    Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow
    Summary
    A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 12:55 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11499",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:55:19.613788Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T12:55:29.374Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T03:48:57.001Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369119 | Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369119"
            },
            {
              "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369119/cti"
            },
            {
              "name": "CVE-2026-11499 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11499"
            },
            {
              "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834888"
            },
            {
              "name": "Submit #888875 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/888875"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:53:40.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11499",
        "datePublished": "2026-06-08T07:00:23.672Z",
        "dateReserved": "2026-06-07T13:23:38.138Z",
        "dateUpdated": "2026-10-02T03:48:57.001Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11498 (GCVE-0-2026-11498)

    Vulnerability from nvd – Published: 2026-06-08 06:45 – Updated: 2026-10-02 03:48
    VLAI
    Title
    Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 12:47 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11498",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:47:31.920390Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:22:24.244Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T03:48:52.157Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369118 | Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369118"
            },
            {
              "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369118/cti"
            },
            {
              "name": "CVE-2026-11498 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11498"
            },
            {
              "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834887"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:53:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11498",
        "datePublished": "2026-06-08T06:45:21.289Z",
        "dateReserved": "2026-06-07T13:22:12.336Z",
        "dateUpdated": "2026-10-02T03:48:52.157Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2910 (GCVE-0-2026-2910)

    Vulnerability from nvd – Published: 2026-02-22 02:32 – Updated: 2026-02-23 19:17
    VLAI
    Title
    Tenda HG9 formPing6 stack-based overflow
    Summary
    A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:17 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347219 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347219 signaturepermissions-required
    https://vuldb.com/?submit.755212 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/12 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2910",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:17:14.139751Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:17:27.114Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T02:32:11.075Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347219 | Tenda HG9 formPing6 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347219"
            },
            {
              "name": "VDB-347219 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347219"
            },
            {
              "name": "Submit #755212 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755212"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/12"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:20:04.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 formPing6 stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2910",
        "datePublished": "2026-02-22T02:32:11.075Z",
        "dateReserved": "2026-02-20T20:14:51.686Z",
        "dateUpdated": "2026-02-23T19:17:27.114Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2909 (GCVE-0-2026-2909)

    Vulnerability from nvd – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:18
    VLAI
    Title
    Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow
    Summary
    A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:18 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347218 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347218 signaturepermissions-required
    https://vuldb.com/?submit.755211 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/11 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2909",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:18:27.278329Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:18:40.226Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Diagnostic Ping Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T02:02:14.122Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347218 | Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347218"
            },
            {
              "name": "VDB-347218 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347218"
            },
            {
              "name": "Submit #755211 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755211"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/11"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:20:02.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2909",
        "datePublished": "2026-02-22T02:02:14.122Z",
        "dateReserved": "2026-02-20T20:14:48.904Z",
        "dateUpdated": "2026-02-23T19:18:40.226Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2908 (GCVE-0-2026-2908)

    Vulnerability from nvd – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:19
    VLAI
    Title
    Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:19 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347217 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347217 signaturepermissions-required
    https://vuldb.com/?submit.755202 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/10 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2908",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:19:17.915757Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:19:51.049Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Loopback Detection Configuration Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T02:02:10.921Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347217 | Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347217"
            },
            {
              "name": "VDB-347217 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347217"
            },
            {
              "name": "Submit #755202 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755202"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/10"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:20:00.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2908",
        "datePublished": "2026-02-22T02:02:10.921Z",
        "dateReserved": "2026-02-20T20:14:45.983Z",
        "dateUpdated": "2026-02-23T19:19:51.049Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2907 (GCVE-0-2026-2907)

    Vulnerability from nvd – Published: 2026-02-22 01:32 – Updated: 2026-02-23 19:23
    VLAI
    Title
    Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow
    Summary
    A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:22 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347216 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347216 signaturepermissions-required
    https://vuldb.com/?submit.755201 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/9 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2907",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:22:46.303895Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:23:03.755Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "GPON Configuration Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T01:32:12.542Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347216 | Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347216"
            },
            {
              "name": "VDB-347216 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347216"
            },
            {
              "name": "Submit #755201 | Tenda HG9  V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755201"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/9"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:19:59.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2907",
        "datePublished": "2026-02-22T01:32:12.542Z",
        "dateReserved": "2026-02-20T20:14:43.142Z",
        "dateUpdated": "2026-02-23T19:23:03.755Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2906 (GCVE-0-2026-2906)

    Vulnerability from nvd – Published: 2026-02-22 01:32 – Updated: 2026-02-24 15:38
    VLAI
    Title
    Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow
    Summary
    A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-24 15:38 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347215 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347215 signaturepermissions-required
    https://vuldb.com/?submit.755193 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/8 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2906",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-24T15:38:13.838475Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-24T15:38:54.600Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Samba Configuration Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T01:32:09.390Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347215 | Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347215"
            },
            {
              "name": "VDB-347215 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347215"
            },
            {
              "name": "Submit #755193 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755193"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/8"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:19:58.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2906",
        "datePublished": "2026-02-22T01:32:09.390Z",
        "dateReserved": "2026-02-20T20:14:40.341Z",
        "dateUpdated": "2026-02-24T15:38:54.600Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2905 (GCVE-0-2026-2905)

    Vulnerability from nvd – Published: 2026-02-22 01:02 – Updated: 2026-02-23 19:13
    VLAI
    Title
    Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow
    Summary
    A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:13 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347214 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347214 signaturepermissions-required
    https://vuldb.com/?submit.755167 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/7 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2905",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:13:05.204806Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:13:59.154Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Wireless Configuration Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T01:02:10.433Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347214 | Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347214"
            },
            {
              "name": "VDB-347214 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347214"
            },
            {
              "name": "Submit #755167 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755167"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/7"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:19:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2905",
        "datePublished": "2026-02-22T01:02:10.433Z",
        "dateReserved": "2026-02-20T20:14:32.380Z",
        "dateUpdated": "2026-02-23T19:13:59.154Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-104610 (GCVE-0-2026-104610)

    Vulnerability from cvelistv5 – Published: 2026-10-02 12:00 – Updated: 2026-10-02 13:50
    VLAI
    Title
    Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 13:49 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/412917 vdb-entrytechnical-description
    https://vuldb.com/vuln/412917/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-104610 third-party-advisory
    https://vuldb.com/submit/962541 third-party-advisory
    https://github.com/Expl0rer-Ct/CVE/issues/1 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-104610",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T13:49:47.985467Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T13:50:12.393Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Web Server"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Expl0rer.Ct (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T12:00:18.544Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-412917 | Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/412917"
            },
            {
              "name": "VDB-412917 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/412917/cti"
            },
            {
              "name": "CVE-2026-104610 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-104610"
            },
            {
              "name": "Submit #962541 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/962541"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/Expl0rer-Ct/CVE/issues/1"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:54:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-104610",
        "datePublished": "2026-10-02T12:00:18.544Z",
        "dateReserved": "2026-10-02T03:49:26.992Z",
        "dateUpdated": "2026-10-02T13:50:12.393Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11553 (GCVE-0-2026-11553)

    Vulnerability from cvelistv5 – Published: 2026-06-08 17:15 – Updated: 2026-10-02 03:49
    VLAI
    Title
    Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 18:49 UTC
    CWE
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11553",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T18:49:04.954919Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T18:49:14.135Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "zhihua xie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T03:49:03.652Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369163 | Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369163"
            },
            {
              "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369163/cti"
            },
            {
              "name": "CVE-2026-11553 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11553"
            },
            {
              "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836778"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:53:43.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11553",
        "datePublished": "2026-06-08T17:15:11.855Z",
        "dateReserved": "2026-06-08T05:43:31.214Z",
        "dateUpdated": "2026-10-02T03:49:03.652Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11499 (GCVE-0-2026-11499)

    Vulnerability from cvelistv5 – Published: 2026-06-08 07:00 – Updated: 2026-10-02 03:48
    VLAI
    Title
    Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow
    Summary
    A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 12:55 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11499",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:55:19.613788Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T12:55:29.374Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T03:48:57.001Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369119 | Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369119"
            },
            {
              "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369119/cti"
            },
            {
              "name": "CVE-2026-11499 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11499"
            },
            {
              "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834888"
            },
            {
              "name": "Submit #888875 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/888875"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:53:40.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11499",
        "datePublished": "2026-06-08T07:00:23.672Z",
        "dateReserved": "2026-06-07T13:23:38.138Z",
        "dateUpdated": "2026-10-02T03:48:57.001Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11498 (GCVE-0-2026-11498)

    Vulnerability from cvelistv5 – Published: 2026-06-08 06:45 – Updated: 2026-10-02 03:48
    VLAI
    Title
    Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 12:47 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Tenda HG7 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11498",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:47:31.920390Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:22:24.244Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T03:48:52.157Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369118 | Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369118"
            },
            {
              "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369118/cti"
            },
            {
              "name": "CVE-2026-11498 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11498"
            },
            {
              "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834887"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-02T05:53:37.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11498",
        "datePublished": "2026-06-08T06:45:21.289Z",
        "dateReserved": "2026-06-07T13:22:12.336Z",
        "dateUpdated": "2026-10-02T03:48:52.157Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2910 (GCVE-0-2026-2910)

    Vulnerability from cvelistv5 – Published: 2026-02-22 02:32 – Updated: 2026-02-23 19:17
    VLAI
    Title
    Tenda HG9 formPing6 stack-based overflow
    Summary
    A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:17 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347219 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347219 signaturepermissions-required
    https://vuldb.com/?submit.755212 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/12 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2910",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:17:14.139751Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:17:27.114Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T02:32:11.075Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347219 | Tenda HG9 formPing6 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347219"
            },
            {
              "name": "VDB-347219 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347219"
            },
            {
              "name": "Submit #755212 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755212"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/12"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:20:04.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 formPing6 stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2910",
        "datePublished": "2026-02-22T02:32:11.075Z",
        "dateReserved": "2026-02-20T20:14:51.686Z",
        "dateUpdated": "2026-02-23T19:17:27.114Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2909 (GCVE-0-2026-2909)

    Vulnerability from cvelistv5 – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:18
    VLAI
    Title
    Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow
    Summary
    A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:18 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347218 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347218 signaturepermissions-required
    https://vuldb.com/?submit.755211 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/11 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2909",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:18:27.278329Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:18:40.226Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Diagnostic Ping Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T02:02:14.122Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347218 | Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347218"
            },
            {
              "name": "VDB-347218 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347218"
            },
            {
              "name": "Submit #755211 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755211"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/11"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:20:02.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2909",
        "datePublished": "2026-02-22T02:02:14.122Z",
        "dateReserved": "2026-02-20T20:14:48.904Z",
        "dateUpdated": "2026-02-23T19:18:40.226Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2908 (GCVE-0-2026-2908)

    Vulnerability from cvelistv5 – Published: 2026-02-22 02:02 – Updated: 2026-02-23 19:19
    VLAI
    Title
    Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow
    Summary
    A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:19 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347217 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347217 signaturepermissions-required
    https://vuldb.com/?submit.755202 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/10 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2908",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:19:17.915757Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:19:51.049Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Loopback Detection Configuration Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T02:02:10.921Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347217 | Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347217"
            },
            {
              "name": "VDB-347217 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347217"
            },
            {
              "name": "Submit #755202 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755202"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/10"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:20:00.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2908",
        "datePublished": "2026-02-22T02:02:10.921Z",
        "dateReserved": "2026-02-20T20:14:45.983Z",
        "dateUpdated": "2026-02-23T19:19:51.049Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2907 (GCVE-0-2026-2907)

    Vulnerability from cvelistv5 – Published: 2026-02-22 01:32 – Updated: 2026-02-23 19:23
    VLAI
    Title
    Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow
    Summary
    A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:22 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347216 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347216 signaturepermissions-required
    https://vuldb.com/?submit.755201 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/9 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2907",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:22:46.303895Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:23:03.755Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "GPON Configuration Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T01:32:12.542Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347216 | Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347216"
            },
            {
              "name": "VDB-347216 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347216"
            },
            {
              "name": "Submit #755201 | Tenda HG9  V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755201"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/9"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:19:59.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2907",
        "datePublished": "2026-02-22T01:32:12.542Z",
        "dateReserved": "2026-02-20T20:14:43.142Z",
        "dateUpdated": "2026-02-23T19:23:03.755Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2906 (GCVE-0-2026-2906)

    Vulnerability from cvelistv5 – Published: 2026-02-22 01:32 – Updated: 2026-02-24 15:38
    VLAI
    Title
    Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow
    Summary
    A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-24 15:38 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347215 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347215 signaturepermissions-required
    https://vuldb.com/?submit.755193 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/8 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2906",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-24T15:38:13.838475Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-24T15:38:54.600Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Samba Configuration Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T01:32:09.390Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347215 | Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347215"
            },
            {
              "name": "VDB-347215 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347215"
            },
            {
              "name": "Submit #755193 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755193"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/8"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:19:58.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2906",
        "datePublished": "2026-02-22T01:32:09.390Z",
        "dateReserved": "2026-02-20T20:14:40.341Z",
        "dateUpdated": "2026-02-24T15:38:54.600Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2905 (GCVE-0-2026-2905)

    Vulnerability from cvelistv5 – Published: 2026-02-22 01:02 – Updated: 2026-02-23 19:13
    VLAI
    Title
    Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow
    Summary
    A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-23 19:13 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/?id.347214 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.347214 signaturepermissions-required
    https://vuldb.com/?submit.755167 third-party-advisory
    https://github.com/QIU-DIE/cve-nneeww/issues/7 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG9 Affected: 300001138
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2905",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T19:13:05.204806Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T19:13:59.154Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Wireless Configuration Endpoint"
              ],
              "product": "HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LINXI666 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-22T01:02:10.433Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-347214 | Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.347214"
            },
            {
              "name": "VDB-347214 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.347214"
            },
            {
              "name": "Submit #755167 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.755167"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/QIU-DIE/cve-nneeww/issues/7"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-20T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T21:19:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2905",
        "datePublished": "2026-02-22T01:02:10.433Z",
        "dateReserved": "2026-02-20T20:14:32.380Z",
        "dateUpdated": "2026-02-23T19:13:59.154Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }