var-202004-0923
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1. NETGEAR GS105E, etc. are all a kind of switchboard of NETGEAR
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-0923", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "fs728tlp", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.26" }, { "model": "gs105pe", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs110emx", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.4" }, { "model": "gs408epp", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.15" }, { "model": "gs808e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.7.0.7" }, { "model": "gs810emx", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.7.1.1" }, { "model": "gs908e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.7.0.3" }, { "model": "gss108e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gss108epp", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.15" }, { "model": "gss116e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.6.0.9" }, { "model": "jgs516pe", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "jgs524pe", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "xs512em", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.1" }, { "model": "xs716e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.6.0.23" }, { "model": "xs724em", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.1" }, { "model": "gs116e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "gs108pe", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.06.08" }, { "model": "xs708e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.6.0.23" }, { "model": "gs105e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs108e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.06.08" }, { "model": "jgs524e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "fs728tlp", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.26" }, { "model": "gs105e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs105pe prosafe plus switch", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs108e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs108pe prosafe plus switch", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs110emx", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.4" }, { "model": "gs116e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "gs408epp", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.15" }, { "model": "gs808e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.7.0.7" }, { "model": "gs810emx", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.7.1.1" }, { "model": "gs105ev2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs108ev3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs108pev3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs116ev2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "jgs524ev2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "xs708ev2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.6.0.23" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-27209" }, { "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "db": "NVD", "id": "CVE-2019-20658" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:fs728tlp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs105e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs105pe_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs108e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs108pe_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs110emx_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs116e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs408epp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs808e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs810emx_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015468" } ] }, "cve": "CVE-2019-20658", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2019-20658", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2019-015468", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2020-27209", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2019-20658", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "id": "CVE-2019-20658", "impactScore": 2.5, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2019-015468", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-20658", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2019-20658", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2019-015468", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2020-27209", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202004-1228", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-27209" }, { "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "db": "CNNVD", "id": "CNNVD-202004-1228" }, { "db": "NVD", "id": "CVE-2019-20658" }, { "db": "NVD", "id": "CVE-2019-20658" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1. NETGEAR GS105E, etc. are all a kind of switchboard of NETGEAR", "sources": [ { "db": "NVD", "id": "CVE-2019-20658" }, { "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "db": "CNVD", "id": "CNVD-2020-27209" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-20658", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2019-015468", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-27209", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-1228", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-27209" }, { "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "db": "CNNVD", "id": "CNNVD-202004-1228" }, { "db": "NVD", "id": "CVE-2019-20658" } ] }, "id": "VAR-202004-0923", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-27209" } ], "trust": 1.3394294463636363 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-27209" } ] }, "last_update_date": "2024-11-23T22:37:25.413000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Sensitive Information Disclosure on Some Switches, PSV-2018-0612", "trust": 0.8, "url": "https://kb.netgear.com/000061481/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Switches-PSV-2018-0612" }, { "title": "Patch for Multiple NETGEAR product information disclosure vulnerabilities (CNVD-2020-27209)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/216869" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=116106" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-27209" }, { "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "db": "CNNVD", "id": "CNNVD-202004-1228" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-200", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "db": "NVD", "id": "CVE-2019-20658" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20658" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061481/security-advisory-for-sensitive-information-disclosure-on-some-switches-psv-2018-0612" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-20658" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-27209" }, { "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "db": "CNNVD", "id": "CNNVD-202004-1228" }, { "db": "NVD", "id": "CVE-2019-20658" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-27209" }, { "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "db": "CNNVD", "id": "CNNVD-202004-1228" }, { "db": "NVD", "id": "CVE-2019-20658" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-05-09T00:00:00", "db": "CNVD", "id": "CNVD-2020-27209" }, { "date": "2020-05-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "date": "2020-04-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1228" }, { "date": "2020-04-15T19:15:13.253000", "db": "NVD", "id": "CVE-2019-20658" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-05-09T00:00:00", "db": "CNVD", "id": "CNVD-2020-27209" }, { "date": "2020-05-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015468" }, { "date": "2020-04-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1228" }, { "date": "2024-11-21T04:38:59.387000", "db": "NVD", "id": "CVE-2019-20658" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Information leakage vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015468" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1228" } ], "trust": 0.6 } }
var-202004-1334
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects JGS516PE before 2017-05-11, JGS524Ev2 before 2017-05-11, JGS524PE before 2017-05-11, GS105Ev2 before 2017-05-11, GS105PE before 2017-05-11, GS108Ev3 before 2017-05-11, GS108PEv3 before 2017-05-11, GS116Ev2 before 2017-05-11, GSS108E before 2017-05-11, GSS116E before 2017-05-11, XS708Ev2 before 2017-05-11, and XS716E before 2017-05-11. NETGEAR GS105E, etc. are all switches from NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to bypass authentication and gain access to switch configuration files and passwords (same subnet). This affects JGS516PE prior to 2017-05-11, JGS524Ev2 prior to 2017-05-11, JGS524PE prior to 2017-05-11, GS105Ev2 prior to 2017-05-11, GS105PE prior to 2017-05-11, GS108Ev3 prior to 2017-05-11, GS108PEv3 prior to 2017-05-11, GS116Ev2 prior to 2017-05-11, GSS108E prior to 2017-05-11, GSS116E prior to 2017-05-11, XS708Ev2 prior to 2017-05-11, and XS716E prior to 2017-05-11
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-1334", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "gss116e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "jgs524e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "gs116e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "gs108e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "xs716e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "gs105e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "xs708e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "jgs516pe", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "gs108pe", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "gs105pe", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "jgs524pe", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "gss108e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2017-05-11" }, { "model": "gs105e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2017/05/11" }, { "model": "gs105pe prosafe plus switch", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2017/05/11" }, { "model": "gs108e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2017/05/11" }, { "model": "gs108pe prosafe plus switch", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2017/05/11" }, { "model": "gs116e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2017/05/11" }, { "model": "gss108e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2017/05/11" }, { "model": "jgs516pe", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2017/05/11" }, { "model": "jgs524e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2017/05/11" }, { "model": "jgs524pe", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2017/05/11" }, { "model": "jgs516pe", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "jgs524ev2", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "jgs524pe", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "gs105ev2", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "gs105pe", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "gs108ev3", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "gs108pev3", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "gs116ev2", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "gss108e", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "gss116e", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "xs708ev2", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "xs716e", "scope": "lte", "trust": 0.6, "vendor": "netgear", "version": "\u003c=2017-05-11" }, { "model": "gs105e", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs105pe", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs108e", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs108pe", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.2.0.5" }, { "model": "gs108pe", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs116e", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "gss108e", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gss116e", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.6.0.9" }, { "model": "jgs516pe", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": null }, { "model": "jgs516pe", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "jgs516pe", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "2.6.0.43" }, { "model": "jgs524e", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "jgs524pe", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "xs708e", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.6.0.23" }, { "model": "xs716e", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.6.0.23" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-83564" }, { "db": "VULMON", "id": "CVE-2017-18862" }, { "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "db": "NVD", "id": "CVE-2017-18862" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:gs105e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs105pe_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs108e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs108pe_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs116e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gss108e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:jgs516pe_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:jgs524e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:jgs524pe_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-014994" } ] }, "cve": "CVE-2017-18862", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2017-18862", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.1, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2017-014994", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-83564", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2017-18862", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2017-014994", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-18862", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2017-014994", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2021-83564", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202004-2261", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2017-18862", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-83564" }, { "db": "VULMON", "id": "CVE-2017-18862" }, { "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "db": "CNNVD", "id": "CNNVD-202004-2261" }, { "db": "NVD", "id": "CVE-2017-18862" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects JGS516PE before 2017-05-11, JGS524Ev2 before 2017-05-11, JGS524PE before 2017-05-11, GS105Ev2 before 2017-05-11, GS105PE before 2017-05-11, GS108Ev3 before 2017-05-11, GS108PEv3 before 2017-05-11, GS116Ev2 before 2017-05-11, GSS108E before 2017-05-11, GSS116E before 2017-05-11, XS708Ev2 before 2017-05-11, and XS716E before 2017-05-11. NETGEAR GS105E, etc. are all switches from NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to bypass authentication and gain access to switch configuration files and passwords (same subnet). This affects JGS516PE prior to 2017-05-11, JGS524Ev2 prior to 2017-05-11, JGS524PE prior to 2017-05-11, GS105Ev2 prior to 2017-05-11, GS105PE prior to 2017-05-11, GS108Ev3 prior to 2017-05-11, GS108PEv3 prior to 2017-05-11, GS116Ev2 prior to 2017-05-11, GSS108E prior to 2017-05-11, GSS116E prior to 2017-05-11, XS708Ev2 prior to 2017-05-11, and XS716E prior to 2017-05-11", "sources": [ { "db": "NVD", "id": "CVE-2017-18862" }, { "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "db": "CNVD", "id": "CNVD-2021-83564" }, { "db": "VULMON", "id": "CVE-2017-18862" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-18862", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2017-014994", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-83564", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-2261", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2017-18862", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-83564" }, { "db": "VULMON", "id": "CVE-2017-18862" }, { "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "db": "CNNVD", "id": "CNNVD-202004-2261" }, { "db": "NVD", "id": "CVE-2017-18862" } ] }, "id": "VAR-202004-1334", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-83564" } ], "trust": 1.3910071815384613 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-83564" } ] }, "last_update_date": "2024-11-23T22:11:30.775000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Authentication Bypass on ProSAFE Web Managed Switches, PSV-2015-0043", "trust": 0.8, "url": "https://kb.netgear.com/000037849/Security-Advisory-for-Authentication-Bypass-on-ProSAFE-Web-Managed-Switches-PSV-2015-0043" }, { "title": "Patch for Multiple NETGEAR product authorization issues and vulnerabilities (CNVD-2021-83564)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/296276" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117353" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-83564" }, { "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "db": "CNNVD", "id": "CNNVD-202004-2261" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-287", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "db": "NVD", "id": "CVE-2017-18862" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-18862" }, { "trust": 1.7, "url": "https://kb.netgear.com/000037849/security-advisory-for-authentication-bypass-on-prosafe-web-managed-switches-psv-2015-0043" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-18862" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-83564" }, { "db": "VULMON", "id": "CVE-2017-18862" }, { "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "db": "CNNVD", "id": "CNNVD-202004-2261" }, { "db": "NVD", "id": "CVE-2017-18862" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-83564" }, { "db": "VULMON", "id": "CVE-2017-18862" }, { "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "db": "CNNVD", "id": "CNNVD-202004-2261" }, { "db": "NVD", "id": "CVE-2017-18862" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-04-29T00:00:00", "db": "CNVD", "id": "CNVD-2021-83564" }, { "date": "2020-04-28T00:00:00", "db": "VULMON", "id": "CVE-2017-18862" }, { "date": "2020-06-01T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "date": "2020-04-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-2261" }, { "date": "2020-04-28T16:15:12.683000", "db": "NVD", "id": "CVE-2017-18862" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-11-04T00:00:00", "db": "CNVD", "id": "CNVD-2021-83564" }, { "date": "2020-05-05T00:00:00", "db": "VULMON", "id": "CVE-2017-18862" }, { "date": "2020-06-01T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-014994" }, { "date": "2020-05-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-2261" }, { "date": "2024-11-21T03:21:07.230000", "db": "NVD", "id": "CVE-2017-18862" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-2261" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Product authentication vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-014994" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-2261" } ], "trust": 0.6 } }
var-202004-0941
Vulnerability from variot
Certain NETGEAR devices are affected by lack of access control at the function level. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS724TPv2 before 1.1.1.29, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1. plural NETGEAR The device contains a vulnerability related to lack of authentication.Information may be obtained and tampered with. NETGEAR GS105E, etc. are all a kind of switchboard of NETGEAR. No detailed vulnerability details are currently available
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-0941", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "fs728tlp", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.26" }, { "model": "gs105pe", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs110emx", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.4" }, { "model": "gs408epp", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.15" }, { "model": "gs808e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.7.0.7" }, { "model": "gs810emx", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.7.1.1" }, { "model": "gs908e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.7.0.3" }, { "model": "gss108e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gss108epp", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.15" }, { "model": "gss116e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.6.0.9" }, { "model": "jgs516pe", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "jgs524pe", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "xs512em", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.1" }, { "model": "xs716e", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.6.0.23" }, { "model": "xs724em", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.1.1" }, { "model": "gs724tp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.1.29" }, { "model": "gs116e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "gs108pe", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.06.08" }, { "model": "xs708e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.6.0.23" }, { "model": "gs105e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs108e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.06.08" }, { "model": "jgs524e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "fs728tlp", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.26" }, { "model": "gs105e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs105pe prosafe plus switch", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs108e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs108pe prosafe plus switch", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs110emx", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.1.4" }, { "model": "gs116e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "gs408epp", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.0.15" }, { "model": "gs724tp", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.1.1.29" }, { "model": "gs808e", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.7.0.7" }, { "model": "gs105ev2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.6.0.4" }, { "model": "gs108ev3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs108pev3", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "2.06.08" }, { "model": "gs116ev2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "gs724tpv2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.1.1.29" }, { "model": "jgs524ev2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "2.6.0.35" }, { "model": "xs708ev2", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "1.6.0.23" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-24418" }, { "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "db": "NVD", "id": "CVE-2019-20676" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:fs728tlp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs105e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs105pe_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs108e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs108pe_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs110emx_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs116e_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs408epp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs724tp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs808e_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015469" } ] }, "cve": "CVE-2019-20676", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CVE-2019-20676", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 1.0, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.6, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2019-015469", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CNVD-2020-24418", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2019-20676", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2019-20676", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.0, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2019-015469", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-20676", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2019-20676", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2019-015469", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2020-24418", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202004-1210", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-24418" }, { "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "db": "CNNVD", "id": "CNNVD-202004-1210" }, { "db": "NVD", "id": "CVE-2019-20676" }, { "db": "NVD", "id": "CVE-2019-20676" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS724TPv2 before 1.1.1.29, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1. plural NETGEAR The device contains a vulnerability related to lack of authentication.Information may be obtained and tampered with. NETGEAR GS105E, etc. are all a kind of switchboard of NETGEAR. No detailed vulnerability details are currently available", "sources": [ { "db": "NVD", "id": "CVE-2019-20676" }, { "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "db": "CNVD", "id": "CNVD-2020-24418" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-20676", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2019-015469", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-24418", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-1210", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-24418" }, { "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "db": "CNNVD", "id": "CNNVD-202004-1210" }, { "db": "NVD", "id": "CVE-2019-20676" } ] }, "id": "VAR-202004-0941", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-24418" } ], "trust": 1.3507586008695651 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-24418" } ] }, "last_update_date": "2024-11-23T23:11:27.368000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Missing Function Level Access Control on Some Switches, PSV-2018-0542", "trust": 0.8, "url": "https://kb.netgear.com/000061463/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Switches-PSV-2018-0542" }, { "title": "Patch for Multiple NETGEAR product access control error vulnerabilities", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/215173" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=116089" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-24418" }, { "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "db": "CNNVD", "id": "CNNVD-202004-1210" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-862", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "db": "NVD", "id": "CVE-2019-20676" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20676" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061463/security-advisory-for-missing-function-level-access-control-on-some-switches-psv-2018-0542" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-20676" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-24418" }, { "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "db": "CNNVD", "id": "CNNVD-202004-1210" }, { "db": "NVD", "id": "CVE-2019-20676" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-24418" }, { "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "db": "CNNVD", "id": "CNNVD-202004-1210" }, { "db": "NVD", "id": "CVE-2019-20676" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-04-24T00:00:00", "db": "CNVD", "id": "CNVD-2020-24418" }, { "date": "2020-05-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "date": "2020-04-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1210" }, { "date": "2020-04-15T20:15:14.333000", "db": "NVD", "id": "CVE-2019-20676" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-04-24T00:00:00", "db": "CNVD", "id": "CNVD-2020-24418" }, { "date": "2020-05-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-015469" }, { "date": "2020-04-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-1210" }, { "date": "2024-11-21T04:39:03.200000", "db": "NVD", "id": "CVE-2019-20676" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Vulnerability in lack of authentication on device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-015469" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-1210" } ], "trust": 0.6 } }
var-201407-0439
Vulnerability from variot
NETGEAR GS108PE Prosafe Plus switches with firmware 1.2.0.5 have a hardcoded password of debugpassword for the ntgruser account, which allows remote attackers to upload firmware or read or modify memory contents, and consequently execute arbitrary code, via a request to (1) produce_burn.cgi, (2) register_debug.cgi, or (3) bootcode_update.cgi. Netgear GS105PE Prosafe Plus Switch firmware version 1.2.0.5 contains hard-coded credentials. (CWE-798). An attacker could exploit this vulnerability to bypass the authentication mechanism and access the affected device without authorization. This may aid in further attacks. The vulnerability is caused by the use of a hard-coded password (debugpassword) for the ntgruser account
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201407-0439", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "gs108pe", "scope": "eq", "trust": 1.6, "vendor": "netgear", "version": "1.2.0.5" }, { "model": "gs108pe", "scope": "eq", "trust": 1.0, "vendor": "netgear", "version": null }, { "model": "gs105pe prosafe plus switch", "scope": null, "trust": 0.8, "vendor": "net gear", "version": null }, { "model": "gs105pe prosafe plus switch", "scope": "eq", "trust": 0.8, "vendor": "net gear", "version": "version 1.2.0.5" }, { "model": "gs108pe prosafe plus switch", "scope": "eq", "trust": 0.6, "vendor": "netgear", "version": "1.2.0.5" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2014-04081" }, { "db": "JVNDB", "id": "JVNDB-2014-003154" }, { "db": "CNNVD", "id": "CNNVD-201407-177" }, { "db": "NVD", "id": "CVE-2014-2969" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/h:netgear:gs105pe", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:gs105pe_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2014-003154" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Marc Olivier Chouinard", "sources": [ { "db": "BID", "id": "68366" } ], "trust": 0.3 }, "cve": "CVE-2014-2969", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CVE-2014-2969", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "ADJACENT NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "availabilityRequirement": "NOT DEFINED", "baseScore": 7.8, "collateralDamagePotential": "LOW", "confidentialityImpact": "COMPLETE", "confidentialityRequirement": "NOT DEFINED", "enviromentalScore": 1.7, "exploitability": "PROOF-OF-CONCEPT", "exploitabilityScore": 6.5, "id": "CVE-2014-2969", "impactScore": 9.2, "integrityImpact": "COMPLETE", "integrityRequirement": "NOT DEFINED", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "remediationLevel": "UNAVAILABLE", "reportConfidence": "UNCOFIRMED", "severity": "HIGH", "targetDistribution": "LOW", "trust": 0.8, "userInteractionRequired": null, "vector_string": "AV:A/AC:L/Au:N/C:C/I:C/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "IPA", "availabilityImpact": "None", "baseScore": 7.8, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2014-003154", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2014-04081", "impactScore": 8.5, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "VHN-70908", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:A/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2014-2969", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2014-2969", "trust": 0.8, "value": "HIGH" }, { "author": "IPA", "id": "JVNDB-2014-003154", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2014-04081", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201407-177", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-70908", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CERT/CC", "id": "VU#143740" }, { "db": "CNVD", "id": "CNVD-2014-04081" }, { "db": "VULHUB", "id": "VHN-70908" }, { "db": "JVNDB", "id": "JVNDB-2014-003154" }, { "db": "CNNVD", "id": "CNNVD-201407-177" }, { "db": "NVD", "id": "CVE-2014-2969" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "NETGEAR GS108PE Prosafe Plus switches with firmware 1.2.0.5 have a hardcoded password of debugpassword for the ntgruser account, which allows remote attackers to upload firmware or read or modify memory contents, and consequently execute arbitrary code, via a request to (1) produce_burn.cgi, (2) register_debug.cgi, or (3) bootcode_update.cgi. Netgear GS105PE Prosafe Plus Switch firmware version 1.2.0.5 contains hard-coded credentials. (CWE-798). An attacker could exploit this vulnerability to bypass the authentication mechanism and access the affected device without authorization. This may aid in further attacks. The vulnerability is caused by the use of a hard-coded password (debugpassword) for the ntgruser account", "sources": [ { "db": "NVD", "id": "CVE-2014-2969" }, { "db": "CERT/CC", "id": "VU#143740" }, { "db": "JVNDB", "id": "JVNDB-2014-003154" }, { "db": "CNVD", "id": "CNVD-2014-04081" }, { "db": "BID", "id": "68366" }, { "db": "VULHUB", "id": "VHN-70908" } ], "trust": 3.24 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.kb.cert.org/vuls/id/143740", "trust": 0.8, "type": "poc" } ], "sources": [ { "db": "CERT/CC", "id": "VU#143740" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2014-2969", "trust": 3.4 }, { "db": "CERT/CC", "id": "VU#143740", "trust": 3.3 }, { "db": "BID", "id": "68366", "trust": 1.0 }, { "db": "JVN", "id": "JVNVU91918249", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2014-003154", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201407-177", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2014-04081", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-70908", "trust": 0.1 } ], "sources": [ { "db": "CERT/CC", "id": "VU#143740" }, { "db": "CNVD", "id": "CNVD-2014-04081" }, { "db": "VULHUB", "id": "VHN-70908" }, { "db": "BID", "id": "68366" }, { "db": "JVNDB", "id": "JVNDB-2014-003154" }, { "db": "CNNVD", "id": "CNNVD-201407-177" }, { "db": "NVD", "id": "CVE-2014-2969" } ] }, "id": "VAR-201407-0439", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2014-04081" }, { "db": "VULHUB", "id": "VHN-70908" } ], "trust": 1.325 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2014-04081" } ] }, "last_update_date": "2024-11-23T21:55:18.930000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Gigabit Plus Switch Series - GS105PE", "trust": 0.8, "url": "http://www.netgear.com/business/products/switches/unmanaged-plus/GS105PE.aspx" }, { "title": "GS105PE", "trust": 0.8, "url": "http://www.netgear.jp/products/details/GS105PE.html" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2014-003154" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-255", "trust": 1.9 }, { "problemtype": "CWE-798", "trust": 0.8 }, { "problemtype": "CWE-Other", "trust": 0.8 } ], "sources": [ { "db": "CERT/CC", "id": "VU#143740" }, { "db": "VULHUB", "id": "VHN-70908" }, { "db": "JVNDB", "id": "JVNDB-2014-003154" }, { "db": "NVD", "id": "CVE-2014-2969" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "http://www.kb.cert.org/vuls/id/143740" }, { "trust": 0.8, "url": "about vulnerability notes" }, { "trust": 0.8, "url": "contact us about this vulnerability" }, { "trust": 0.8, "url": "provide a vendor statement" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-2969" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu91918249/index.html" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-2969" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/68366" } ], "sources": [ { "db": "CERT/CC", "id": "VU#143740" }, { "db": "CNVD", "id": "CNVD-2014-04081" }, { "db": "VULHUB", "id": "VHN-70908" }, { "db": "JVNDB", "id": "JVNDB-2014-003154" }, { "db": "CNNVD", "id": "CNNVD-201407-177" }, { "db": "NVD", "id": "CVE-2014-2969" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CERT/CC", "id": "VU#143740" }, { "db": "CNVD", "id": "CNVD-2014-04081" }, { "db": "VULHUB", "id": "VHN-70908" }, { "db": "BID", "id": "68366" }, { "db": "JVNDB", "id": "JVNDB-2014-003154" }, { "db": "CNNVD", "id": "CNNVD-201407-177" }, { "db": "NVD", "id": "CVE-2014-2969" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2014-07-03T00:00:00", "db": "CERT/CC", "id": "VU#143740" }, { "date": "2014-07-07T00:00:00", "db": "CNVD", "id": "CNVD-2014-04081" }, { "date": "2014-07-07T00:00:00", "db": "VULHUB", "id": "VHN-70908" }, { "date": "2014-07-03T00:00:00", "db": "BID", "id": "68366" }, { "date": "2014-07-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2014-003154" }, { "date": "2014-07-08T00:00:00", "db": "CNNVD", "id": "CNNVD-201407-177" }, { "date": "2014-07-07T11:01:29.993000", "db": "NVD", "id": "CVE-2014-2969" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2014-07-08T00:00:00", "db": "CERT/CC", "id": "VU#143740" }, { "date": "2014-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2014-04081" }, { "date": "2014-07-07T00:00:00", "db": "VULHUB", "id": "VHN-70908" }, { "date": "2014-07-03T00:00:00", "db": "BID", "id": "68366" }, { "date": "2014-07-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2014-003154" }, { "date": "2014-07-08T00:00:00", "db": "CNNVD", "id": "CNNVD-201407-177" }, { "date": "2024-11-21T02:07:15.627000", "db": "NVD", "id": "CVE-2014-2969" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "specific network environment", "sources": [ { "db": "CNNVD", "id": "CNNVD-201407-177" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear GS105PE Prosafe Plus Switch contains hard-coded login credentials", "sources": [ { "db": "CERT/CC", "id": "VU#143740" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "trust management", "sources": [ { "db": "CNNVD", "id": "CNNVD-201407-177" } ], "trust": 0.6 } }
cve-2019-20658
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:46:10.329Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061481/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Switches-PSV-2018-0612" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-15T18:47:25", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061481/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Switches-PSV-2018-0612" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20658", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061481/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Switches-PSV-2018-0612", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061481/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Switches-PSV-2018-0612" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20658", "datePublished": "2020-04-15T18:47:25", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:46:10.329Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-20676
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:46:10.323Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061463/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Switches-PSV-2018-0542" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS724TPv2 before 1.1.1.29, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:N/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-15T19:14:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061463/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Switches-PSV-2018-0542" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20676", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS724TPv2 before 1.1.1.29, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:L/A:N/C:H/I:H/PR:H/S:U/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061463/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Switches-PSV-2018-0542", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061463/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Switches-PSV-2018-0542" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20676", "datePublished": "2020-04-15T19:14:05", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:46:10.323Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2014-2969
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
http://www.kb.cert.org/vuls/id/143740 | third-party-advisory, x_refsource_CERT-VN |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T10:28:46.349Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VU#143740", "tags": [ "third-party-advisory", "x_refsource_CERT-VN", "x_transferred" ], "url": "http://www.kb.cert.org/vuls/id/143740" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2014-07-03T00:00:00", "descriptions": [ { "lang": "en", "value": "NETGEAR GS108PE Prosafe Plus switches with firmware 1.2.0.5 have a hardcoded password of debugpassword for the ntgruser account, which allows remote attackers to upload firmware or read or modify memory contents, and consequently execute arbitrary code, via a request to (1) produce_burn.cgi, (2) register_debug.cgi, or (3) bootcode_update.cgi." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2014-07-07T05:57:01", "orgId": "37e5125f-f79b-445b-8fad-9564f167944b", "shortName": "certcc" }, "references": [ { "name": "VU#143740", "tags": [ "third-party-advisory", "x_refsource_CERT-VN" ], "url": "http://www.kb.cert.org/vuls/id/143740" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2014-2969", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "NETGEAR GS108PE Prosafe Plus switches with firmware 1.2.0.5 have a hardcoded password of debugpassword for the ntgruser account, which allows remote attackers to upload firmware or read or modify memory contents, and consequently execute arbitrary code, via a request to (1) produce_burn.cgi, (2) register_debug.cgi, or (3) bootcode_update.cgi." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "VU#143740", "refsource": "CERT-VN", "url": "http://www.kb.cert.org/vuls/id/143740" } ] } } } }, "cveMetadata": { "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "assignerShortName": "certcc", "cveId": "CVE-2014-2969", "datePublished": "2014-07-07T10:00:00", "dateReserved": "2014-04-21T00:00:00", "dateUpdated": "2024-08-06T10:28:46.349Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-18862
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T21:37:44.285Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000037849/Security-Advisory-for-Authentication-Bypass-on-ProSAFE-Web-Managed-Switches-PSV-2015-0043" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2017-05-11T00:00:00", "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects JGS516PE before 2017-05-11, JGS524Ev2 before 2017-05-11, JGS524PE before 2017-05-11, GS105Ev2 before 2017-05-11, GS105PE before 2017-05-11, GS108Ev3 before 2017-05-11, GS108PEv3 before 2017-05-11, GS116Ev2 before 2017-05-11, GSS108E before 2017-05-11, GSS116E before 2017-05-11, XS708Ev2 before 2017-05-11, and XS716E before 2017-05-11." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-28T15:54:25", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000037849/Security-Advisory-for-Authentication-Bypass-on-ProSAFE-Web-Managed-Switches-PSV-2015-0043" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-18862", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects JGS516PE before 2017-05-11, JGS524Ev2 before 2017-05-11, JGS524PE before 2017-05-11, GS105Ev2 before 2017-05-11, GS105PE before 2017-05-11, GS108Ev3 before 2017-05-11, GS108PEv3 before 2017-05-11, GS116Ev2 before 2017-05-11, GSS108E before 2017-05-11, GSS116E before 2017-05-11, XS708Ev2 before 2017-05-11, and XS716E before 2017-05-11." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000037849/Security-Advisory-for-Authentication-Bypass-on-ProSAFE-Web-Managed-Switches-PSV-2015-0043", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000037849/Security-Advisory-for-Authentication-Bypass-on-ProSAFE-Web-Managed-Switches-PSV-2015-0043" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-18862", "datePublished": "2020-04-28T15:54:25", "dateReserved": "2020-04-27T00:00:00", "dateUpdated": "2024-08-05T21:37:44.285Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cret@cert.org | http://www.kb.cert.org/vuls/id/143740 | US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.kb.cert.org/vuls/id/143740 | US Government Resource |
Vendor | Product | Version | |
---|---|---|---|
netgear | gs108pe_firmware | 1.2.0.5 | |
netgear | gs108pe | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs108pe_firmware:1.2.0.5:*:*:*:*:*:*:*", "matchCriteriaId": "9DFD4269-4863-4611-85A5-E0221AD2C423", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs108pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "E0244D5C-C430-4649-8990-6817901F0033", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "NETGEAR GS108PE Prosafe Plus switches with firmware 1.2.0.5 have a hardcoded password of debugpassword for the ntgruser account, which allows remote attackers to upload firmware or read or modify memory contents, and consequently execute arbitrary code, via a request to (1) produce_burn.cgi, (2) register_debug.cgi, or (3) bootcode_update.cgi." }, { "lang": "es", "value": "Switches NETGEAR GS108PE Prosafe Plus con firmware 1.2.0.5 tienen una contrase\u00f1a embebida de debugpassword para la cuenta ntgruser, lo que permite a atacantes remotos subir firmware o leer o modificar los contenidos de la memoria, y como consecuencia ejecutar c\u00f3digo arbitrario, a trav\u00e9s de una solicitud en (1) produce_burn.cgi, (2) register_debug.cgi, o (3) bootcode_update.cgi." } ], "id": "CVE-2014-2969", "lastModified": "2024-11-21T02:07:15.627", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2014-07-07T11:01:29.993", "references": [ { "source": "cret@cert.org", "tags": [ "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/143740" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/143740" } ], "sourceIdentifier": "cret@cert.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-255" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | fs728tlp_firmware | * | |
netgear | fs728tlp | - | |
netgear | gs105e_firmware | * | |
netgear | gs105e | v2 | |
netgear | gs105pe_firmware | * | |
netgear | gs105pe | - | |
netgear | gs108e_firmware | * | |
netgear | gs108e | v3 | |
netgear | gs108pe_firmware | * | |
netgear | gs108pe | v3 | |
netgear | gs110emx_firmware | * | |
netgear | gs110emx | - | |
netgear | gs116e_firmware | * | |
netgear | gs116e | v2 | |
netgear | gs408epp_firmware | * | |
netgear | gs408epp | - | |
netgear | gs808e_firmware | * | |
netgear | gs808e | - | |
netgear | gs810emx_firmware | * | |
netgear | gs810emx | - | |
netgear | gs908e_firmware | * | |
netgear | gs908e | - | |
netgear | gss108e_firmware | * | |
netgear | gss108e | - | |
netgear | gss108epp_firmware | * | |
netgear | gss108epp | - | |
netgear | gss116e_firmware | * | |
netgear | gss116e | - | |
netgear | jgs516pe_firmware | * | |
netgear | jgs516pe | - | |
netgear | jgs524e_firmware | * | |
netgear | jgs524e | v2 | |
netgear | jgs524pe_firmware | * | |
netgear | jgs524pe | - | |
netgear | xs512em_firmware | * | |
netgear | xs512em | - | |
netgear | xs708e_firmware | * | |
netgear | xs708e | v2 | |
netgear | xs716e_firmware | * | |
netgear | xs716e | - | |
netgear | xs724em_firmware | * | |
netgear | xs724em | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:fs728tlp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A5F92D9-065E-40AA-BDBA-73E2671C961A", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:fs728tlp:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4EEBDAE-AE10-43F2-BB8A-73CE293848D9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs105e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FBF196D1-A0B3-443D-88A0-AA2E096C57F6", "versionEndExcluding": "1.6.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs105e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "DD993BAB-DF89-41AB-936B-9C6F280BAE1D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs105pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0E0CE18-6EA8-41F5-8984-1FEB91561127", "versionEndExcluding": "1.6.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs105pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "211D1DBE-5D7A-4309-A125-126AF2A16647", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs108e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDE4B26A-8305-40B9-8A70-59626881EEEA", "versionEndExcluding": "2.06.08", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs108e:v3:*:*:*:*:*:*:*", "matchCriteriaId": "5579C6E3-866F-4E6A-BD4C-0A1239DE5699", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs108pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "114E9F01-DD89-488E-9D95-33C420AEC7CD", "versionEndExcluding": "2.06.08", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs108pe:v3:*:*:*:*:*:*:*", "matchCriteriaId": "3DA97C4B-C592-4418-8F3B-24C891D3C830", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs110emx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D83E3054-7E97-49C1-B694-B0118200ACEC", "versionEndExcluding": "1.0.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs110emx:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E1EEC50-F8C6-4B34-AB0A-EC5466FF7A74", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs116e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8377DD76-5028-4BB1-B670-453ECCB9BE2E", "versionEndExcluding": "2.6.0.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "6DA5EF92-9B28-4C81-8A95-C5BCEC19591A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs408epp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A902F828-C55A-45B9-81D5-641FFE0ACD2D", "versionEndExcluding": "1.0.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs408epp:-:*:*:*:*:*:*:*", "matchCriteriaId": "86E8C803-F6E4-4CFD-B9BA-D83A7C5269E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs808e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D0DC63B1-22DB-4509-A468-9D1B63C997E7", "versionEndExcluding": "1.7.0.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs808e:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FBE41AE-2001-4539-9F63-710EDEE42629", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs810emx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8E8C971-788E-4D6D-B8BB-B65B2813EE5C", "versionEndExcluding": "1.7.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs810emx:-:*:*:*:*:*:*:*", "matchCriteriaId": "91F71973-C209-4401-B887-9399F9552D7D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs908e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7D4E120D-3609-40F0-86B3-E7A2BC774D40", "versionEndExcluding": "1.7.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs908e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6CA61D2-1B85-4C5F-86CA-AB1F877243FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gss108e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3350D6E6-522C-4D9F-9D74-EE3A2FB9177E", "versionEndExcluding": "1.6.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gss108e:-:*:*:*:*:*:*:*", "matchCriteriaId": "8244C4BA-F166-4C32-BF43-0964CD99921B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gss108epp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2106BBF-F216-4CBE-915C-B9680BB8B4EC", "versionEndExcluding": "1.0.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gss108epp:-:*:*:*:*:*:*:*", "matchCriteriaId": "2EF32417-92E9-4D8B-913A-539A473A2673", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gss116e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5987DE76-B142-43AD-A06A-EED97FBEDC25", "versionEndExcluding": "1.6.0.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gss116e:-:*:*:*:*:*:*:*", "matchCriteriaId": "0C7E2A39-F250-49EB-AE39-A1745B8F1569", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jgs516pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C97166D-7ED9-477D-A246-113BAFFED0C5", "versionEndExcluding": "2.6.0.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCBC0DAB-226E-4C95-9818-7758D37EFD10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jgs524e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "573A1DF4-2441-4B8C-9A01-6CC6BAF2B48E", "versionEndExcluding": "2.6.0.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jgs524e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CFF899BD-AA1E-4C47-BCFD-5E32F75F538A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jgs524pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32DC5F31-3757-4739-8A10-F44DA2637080", "versionEndExcluding": "2.6.0.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jgs524pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4A32288-19B5-4A8F-B883-FCC326B7032D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs512em_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A39A00BE-2EAA-4893-AE8C-EB5B15C1E8DC", "versionEndExcluding": "1.0.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs512em:-:*:*:*:*:*:*:*", "matchCriteriaId": "48FCC8F7-1043-4069-924D-0124FE5D10B0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs708e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "43A13AEB-F9FC-4F7D-812E-F28CE368F9E8", "versionEndExcluding": "1.6.0.23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs708e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "FD93BF51-A52C-422F-BB05-63CF9E97D3B7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs716e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F96E693-D402-4ECB-B2E1-28A06810B9F4", "versionEndExcluding": "1.6.0.23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs716e:-:*:*:*:*:*:*:*", "matchCriteriaId": "6C6BBBDF-8E4C-42B3-9B23-C0970F5C4B7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs724em_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C642EB2-F5F9-43B9-8F14-EF70F2429A46", "versionEndExcluding": "1.0.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs724em:-:*:*:*:*:*:*:*", "matchCriteriaId": "30918F59-D8C5-4A49-A10D-A5703261CCE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial. Esto afecta a FS728TLP versiones anteriores a 1.0.1.26, GS105Ev2 versiones anteriores a 1.6.0.4, GS105PE versiones anteriores a 1.6.0.4, GS108Ev3 versiones anteriores a 2.06.08, GS108PEv3 versiones anteriores a 2.06.08, GS110EMX versiones anteriores a 1.0.1.4, GS116Ev2 versiones anteriores a 2.6.0.35, GS408EPP versiones anteriores a 1.0.0.15, GS808E versiones anteriores a 1.7.0.7, GS810EMX versiones anteriores a 1.7.1.1, GS908E versiones anteriores a 1.7.0.3, GSS108E versiones anteriores a 1.6.0.4, GSS108EPP versiones anteriores a 1.0.0.15, GSS116E versiones anteriores a 1.6.0.9, JGS516PE versiones anteriores a 2.6.0.35, JGS524Ev2 antes 2.6.0.35, JGS524PE antes 2.6.0.35, XS512EM versiones anteriores a 1.0.1.1, XS708Ev2 versiones anteriores a 1.6.0.23, XS716E versiones anteriores a 1.6.0.23 y XS724EM versiones anteriores a 1.0.1.1." } ], "id": "CVE-2019-20658", "lastModified": "2024-11-21T04:38:59.387", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 2.5, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-15T19:15:13.253", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061481/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Switches-PSV-2018-0612" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061481/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Switches-PSV-2018-0612" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:fs728tlp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A5F92D9-065E-40AA-BDBA-73E2671C961A", "versionEndExcluding": "1.0.1.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:fs728tlp:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4EEBDAE-AE10-43F2-BB8A-73CE293848D9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs105e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FBF196D1-A0B3-443D-88A0-AA2E096C57F6", "versionEndExcluding": "1.6.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs105e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "DD993BAB-DF89-41AB-936B-9C6F280BAE1D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs105pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0E0CE18-6EA8-41F5-8984-1FEB91561127", "versionEndExcluding": "1.6.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs105pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "211D1DBE-5D7A-4309-A125-126AF2A16647", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs108e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDE4B26A-8305-40B9-8A70-59626881EEEA", "versionEndExcluding": "2.06.08", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs108e:v3:*:*:*:*:*:*:*", "matchCriteriaId": "5579C6E3-866F-4E6A-BD4C-0A1239DE5699", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs108pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "114E9F01-DD89-488E-9D95-33C420AEC7CD", "versionEndExcluding": "2.06.08", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs108pe:v3:*:*:*:*:*:*:*", "matchCriteriaId": "3DA97C4B-C592-4418-8F3B-24C891D3C830", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs110emx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D83E3054-7E97-49C1-B694-B0118200ACEC", "versionEndExcluding": "1.0.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs110emx:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E1EEC50-F8C6-4B34-AB0A-EC5466FF7A74", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs116e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8377DD76-5028-4BB1-B670-453ECCB9BE2E", "versionEndExcluding": "2.6.0.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "6DA5EF92-9B28-4C81-8A95-C5BCEC19591A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs408epp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A902F828-C55A-45B9-81D5-641FFE0ACD2D", "versionEndExcluding": "1.0.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs408epp:-:*:*:*:*:*:*:*", "matchCriteriaId": "86E8C803-F6E4-4CFD-B9BA-D83A7C5269E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs724tp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0515B176-5785-4ABB-BE14-7E2B1766325A", "versionEndExcluding": "1.1.1.29", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs724tp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "E871CCB4-8093-44AE-B289-CF81F82A9DB8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs808e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D0DC63B1-22DB-4509-A468-9D1B63C997E7", "versionEndExcluding": "1.7.0.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs808e:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FBE41AE-2001-4539-9F63-710EDEE42629", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs810emx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8E8C971-788E-4D6D-B8BB-B65B2813EE5C", "versionEndExcluding": "1.7.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs810emx:-:*:*:*:*:*:*:*", "matchCriteriaId": "91F71973-C209-4401-B887-9399F9552D7D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs908e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7D4E120D-3609-40F0-86B3-E7A2BC774D40", "versionEndExcluding": "1.7.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs908e:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6CA61D2-1B85-4C5F-86CA-AB1F877243FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gss108e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3350D6E6-522C-4D9F-9D74-EE3A2FB9177E", "versionEndExcluding": "1.6.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gss108e:-:*:*:*:*:*:*:*", "matchCriteriaId": "8244C4BA-F166-4C32-BF43-0964CD99921B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gss108epp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2106BBF-F216-4CBE-915C-B9680BB8B4EC", "versionEndExcluding": "1.0.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gss108epp:-:*:*:*:*:*:*:*", "matchCriteriaId": "2EF32417-92E9-4D8B-913A-539A473A2673", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gss116e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5987DE76-B142-43AD-A06A-EED97FBEDC25", "versionEndExcluding": "1.6.0.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gss116e:-:*:*:*:*:*:*:*", "matchCriteriaId": "0C7E2A39-F250-49EB-AE39-A1745B8F1569", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jgs516pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C97166D-7ED9-477D-A246-113BAFFED0C5", "versionEndExcluding": "2.6.0.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCBC0DAB-226E-4C95-9818-7758D37EFD10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jgs524e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "573A1DF4-2441-4B8C-9A01-6CC6BAF2B48E", "versionEndExcluding": "2.6.0.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jgs524e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CFF899BD-AA1E-4C47-BCFD-5E32F75F538A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jgs524pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32DC5F31-3757-4739-8A10-F44DA2637080", "versionEndExcluding": "2.6.0.35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jgs524pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4A32288-19B5-4A8F-B883-FCC326B7032D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs512em_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A39A00BE-2EAA-4893-AE8C-EB5B15C1E8DC", "versionEndExcluding": "1.0.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs512em:-:*:*:*:*:*:*:*", "matchCriteriaId": "48FCC8F7-1043-4069-924D-0124FE5D10B0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs708e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "43A13AEB-F9FC-4F7D-812E-F28CE368F9E8", "versionEndExcluding": "1.6.0.23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs708e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "FD93BF51-A52C-422F-BB05-63CF9E97D3B7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs716e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F96E693-D402-4ECB-B2E1-28A06810B9F4", "versionEndExcluding": "1.6.0.23", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs716e:-:*:*:*:*:*:*:*", "matchCriteriaId": "6C6BBBDF-8E4C-42B3-9B23-C0970F5C4B7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs724em_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C642EB2-F5F9-43B9-8F14-EF70F2429A46", "versionEndExcluding": "1.0.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs724em:-:*:*:*:*:*:*:*", "matchCriteriaId": "30918F59-D8C5-4A49-A10D-A5703261CCE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects FS728TLP before 1.0.1.26, GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS108Ev3 before 2.06.08, GS108PEv3 before 2.06.08, GS110EMX before 1.0.1.4, GS116Ev2 before 2.6.0.35, GS408EPP before 1.0.0.15, GS724TPv2 before 1.1.1.29, GS808E before 1.7.0.7, GS810EMX before 1.7.1.1, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, GSS108EPP before 1.0.0.15, GSS116E before 1.6.0.9, JGS516PE before 2.6.0.35, JGS524Ev2 before 2.6.0.35, JGS524PE before 2.6.0.35, XS512EM before 1.0.1.1, XS708Ev2 before 1.6.0.23, XS716E before 1.6.0.23, and XS724EM before 1.0.1.1." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una falta de control de acceso en el nivel de funci\u00f3n. Esto afecta a FS728TLP versiones anteriores a 1.0.1.26, GS105Ev2 versiones anteriores a 1.6.0.4, GS105PE versiones anteriores a 1.6.0.4, GS108Ev3 versiones anteriores a 2.06.08, GS108PEv3 versiones anteriores a 2.06.08, GS110EMX versiones anteriores a 1.0.1.4, GS116Ev2 versiones anteriores a 2.6.0.35, GS408EPP versiones anteriores a 1.0.0.15, GS724TPv2 versiones anteriores a 1.1.1.29, GS808E versiones anteriores a 1.7.0.7, GS810EMX versiones anteriores a 1.7.1.1, GS908E versiones anteriores a 1.7.0.3, GSS108E versiones anteriores a 1.6.0.4, GSS108EPP versiones anteriores a 1.0.0.15, GSS116E versiones anteriores a 1.6.0.9, JGS516PE versiones anteriores a 2.6.0.35, JGS524Ev2 versiones anteriores a 2.6.0.35, JGS524PE versiones anteriores a 2.6.0.35, XS512EM versiones anteriores a 1.0.1.1, XS708Ev2 versiones anteriores a 1.6.0.23, XS716E versiones anteriores a 1.6.0.23 y XS724EM versiones anteriores a 1.0.1.1." } ], "id": "CVE-2019-20676", "lastModified": "2024-11-21T04:39:03.200", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" }, "exploitabilityScore": 0.8, "impactScore": 5.2, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-15T20:15:14.333", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061463/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Switches-PSV-2018-0542" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061463/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Switches-PSV-2018-0542" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-862" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | jgs516pe_firmware | * | |
netgear | jgs516pe | - | |
netgear | jgs524e_firmware | * | |
netgear | jgs524e | v2 | |
netgear | jgs524pe_firmware | * | |
netgear | jgs524pe | - | |
netgear | gs105e_firmware | * | |
netgear | gs105e | v2 | |
netgear | gs105pe_firmware | * | |
netgear | gs105pe | - | |
netgear | gs108e_firmware | * | |
netgear | gs108e | v3 | |
netgear | gs108pe_firmware | * | |
netgear | gs108pe | v3 | |
netgear | gs116e_firmware | * | |
netgear | gs116e | v2 | |
netgear | gss108e_firmware | * | |
netgear | gss108e | - | |
netgear | gss116e_firmware | * | |
netgear | gss116e | - | |
netgear | xs708e_firmware | * | |
netgear | xs708e | v2 | |
netgear | xs716e_firmware | * | |
netgear | xs716e | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jgs516pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "49892DB9-4B99-46FC-A353-C5AEAF93918F", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCBC0DAB-226E-4C95-9818-7758D37EFD10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jgs524e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F28D3423-ABA9-47A4-AE74-75019D649BA8", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jgs524e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "CFF899BD-AA1E-4C47-BCFD-5E32F75F538A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:jgs524pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0774BAE9-FF47-4785-9AA0-86A594335FBA", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:jgs524pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4A32288-19B5-4A8F-B883-FCC326B7032D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs105e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "187CA489-3136-4889-AB0F-3ADA5C7D9C89", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs105e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "DD993BAB-DF89-41AB-936B-9C6F280BAE1D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs105pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "288AED3B-8007-4650-9CB2-3342A345533C", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs105pe:-:*:*:*:*:*:*:*", "matchCriteriaId": "211D1DBE-5D7A-4309-A125-126AF2A16647", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs108e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8A85C689-1FBB-4799-9C27-34C7F6D0CA0A", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs108e:v3:*:*:*:*:*:*:*", "matchCriteriaId": "5579C6E3-866F-4E6A-BD4C-0A1239DE5699", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs108pe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A6812FA4-1665-4CB5-9C89-DBC58557A742", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs108pe:v3:*:*:*:*:*:*:*", "matchCriteriaId": "3DA97C4B-C592-4418-8F3B-24C891D3C830", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gs116e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CE2876A-58F5-4892-89DD-E674A3DE96F1", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "6DA5EF92-9B28-4C81-8A95-C5BCEC19591A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gss108e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48100EBE-BBE1-4278-8F71-A4A6F758B96A", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gss108e:-:*:*:*:*:*:*:*", "matchCriteriaId": "8244C4BA-F166-4C32-BF43-0964CD99921B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:gss116e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "69553993-8804-48F4-B408-DDA852B048C8", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:gss116e:-:*:*:*:*:*:*:*", "matchCriteriaId": "0C7E2A39-F250-49EB-AE39-A1745B8F1569", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs708e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB82FC08-625B-496D-93EB-2673E0147832", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs708e:v2:*:*:*:*:*:*:*", "matchCriteriaId": "FD93BF51-A52C-422F-BB05-63CF9E97D3B7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xs716e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EAB20EA0-D4CF-47D7-8152-45CD65B3FC65", "versionEndExcluding": "2017-05-11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xs716e:-:*:*:*:*:*:*:*", "matchCriteriaId": "6C6BBBDF-8E4C-42B3-9B23-C0970F5C4B7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects JGS516PE before 2017-05-11, JGS524Ev2 before 2017-05-11, JGS524PE before 2017-05-11, GS105Ev2 before 2017-05-11, GS105PE before 2017-05-11, GS108Ev3 before 2017-05-11, GS108PEv3 before 2017-05-11, GS116Ev2 before 2017-05-11, GSS108E before 2017-05-11, GSS116E before 2017-05-11, XS708Ev2 before 2017-05-11, and XS716E before 2017-05-11." }, { "lang": "es", "value": "Determinados dispositivos de NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a JGS516PE antes del 11-05-2017, JGS524Ev2 antes del 11-05-2017, JGS524PE antes del 11-05-2017, GS105Ev2 antes del 11-05-2017, GS105PE antes del 11-05-2017, GS108Ev3 antes del 11-05-2017, GS108PEv3 antes del 11-05-2017, GS116Ev2 antes del 11-05-2017, GSS108E antes del 11-05-2017, GSS116E antes del 11-05-2017, XS708Ev2 antes del 11-05-2017, y XS716E antes del 11-05-2017." } ], "id": "CVE-2017-18862", "lastModified": "2024-11-21T03:21:07.230", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-04-28T16:15:12.683", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000037849/Security-Advisory-for-Authentication-Bypass-on-ProSAFE-Web-Managed-Switches-PSV-2015-0043" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000037849/Security-Advisory-for-Authentication-Bypass-on-ProSAFE-Web-Managed-Switches-PSV-2015-0043" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }