    <item>
      <title>fkie_cve-2026-71925</title>
      <link>https://vulnerability.circl.lu/vuln/fkie_cve-2026-71925</link>
      <description>&lt;p&gt;Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device&amp;#39;s web management interface.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device&amp;#39;s web management interface.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://vulnerability.circl.lu/vuln/fkie_cve-2026-71925</guid>
    </item>
    <item>
      <title>GHSA-f6x9-q3vc-f2xw</title>
      <link>https://vulnerability.circl.lu/vuln/ghsa-f6x9-q3vc-f2xw</link>
      <description>&lt;p&gt;Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device&amp;#39;s web management interface.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device&amp;#39;s web management interface.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://vulnerability.circl.lu/vuln/ghsa-f6x9-q3vc-f2xw</guid>
    </item>
    <item>
      <title>NCSC-2026-0328 — Kwetsbaarheden verholpen in DrayTek VigorSwitch</title>
      <link>https://vulnerability.circl.lu/vuln/ncsc-2026-0328</link>
      <description>NCSC-2026-0328</description>
      <guid isPermaLink="false">https://vulnerability.circl.lu/vuln/ncsc-2026-0328</guid>
    </item>