<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://vulnerability.circl.lu/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-03T13:16:39.569323+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>info@circl.lu</email>
  </author>
  <link href="https://vulnerability.circl.lu" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://vulnerability.circl.lu/vuln/fkie_cve-2026-18278</id>
    <title>fkie_cve-2026-18278</title>
    <updated>2026-10-03T13:16:39.588228+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>Sony XAV-9500ES prh_l2_decode_packet Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Sony XAV-9500ES devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.</p>
<p>The specific flaw exists within the handling of Bluetooth L2CAP packets. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-28990.</p></div>
    </content>
    <link href="https://vulnerability.circl.lu/vuln/fkie_cve-2026-18278"/>
  </entry>
  <entry>
    <id>https://vulnerability.circl.lu/vuln/ghsa-vv43-p65q-97r5</id>
    <title>GHSA-vv43-p65q-97r5</title>
    <updated>2026-10-03T13:16:39.588578+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>Sony XAV-9500ES prh_l2_decode_packet Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Sony XAV-9500ES devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.</p>
<p>The specific flaw exists within the handling of Bluetooth L2CAP packets. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-28990.</p></div>
    </content>
    <link href="https://vulnerability.circl.lu/vuln/ghsa-vv43-p65q-97r5"/>
  </entry>
</feed>
