  <entry>
    <id>https://vulnerability.circl.lu/vuln/cve-2022-1118</id>
    <title>CVE-2022-1118 — Rockwell Automation ISaGRAF Deserialization of Untrusted Data</title>
    <updated>2026-10-04T11:41:57.146968+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> Rockwell Automation Connected Component Workbench, Rockwell Automation ISaGRAF Workbench, Rockwell Automation Safety Instrumented Systems Workstation</p>
<p>Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited</p></div>
    </content>
    <link href="https://vulnerability.circl.lu/vuln/cve-2022-1118"/>
  </entry>
  <entry>
    <id>https://vulnerability.circl.lu/vuln/icsa-22-095-01</id>
    <title>ICSA-22-095-01 — Rockwell Automation ISaGRAF</title>
    <updated>2026-10-04T11:41:57.147109+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Connected Components Workbench, ISaGRAF Workbench, and Safety Instrumented System Workstation do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited.CVE-2022-1118 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H).</p>
      </div>
    </content>
    <link href="https://vulnerability.circl.lu/vuln/icsa-22-095-01"/>
  </entry>